ArticleEuropean radiology experimental2022

Developing and testing a robotic MRI/CT fusion biopsy technique using a purpose-built interventional phantom.

Edward W Johnston, Nicos Fotiadis, Craig Cummings, Jodie Basso, Toby Tyne, Joost Lameijer, Christina Messiou, Dow-Mu Koh, Jessica M Winfield

Abstract read
In one paragraph

Article in European radiology experimental, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Review
  6. Bone biopsies guided by augmented reality: a pilot study.European radiology experimental · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Edward W JohnstonRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK. edwilliamjohnston@gmail.com.ORCID 0000-0002-8504-2968
Nicos FotiadisRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK.
Craig CummingsInstitute of Cancer Research, 123 Old Brompton Road, London, SW73RP, UK.
Jodie BassoRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK.
Toby TyneInstitute of Cancer Research, 123 Old Brompton Road, London, SW73RP, UK.
Joost LameijerRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK.
Christina MessiouRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK.
Dow-Mu KohRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK.
Jessica M WinfieldRoyal Marsden Hospital, 203 Fulham Road, London, SW3 6JJ, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMagnetic resonance imaging (MRI) can be used to target tumour components in biopsy procedures, while the ability to precisely correlate histology and MRI signal is crucial for imaging biomarker validation. Robotic MRI/computed tomography (CT) fusion biopsy offers the potential for this without in-gantry biopsy, although requires development.

methodsTest-retest T1 and T2 relaxation times, attenuation (Hounsfield units, HU), and biopsy core quality were prospectively assessed (January-December 2021) in a range of gelatin, agar, and mixed gelatin/agar solutions of differing concentrations on days 1 and 8 after manufacture. Suitable materials were chosen, and four biopsy phantoms were constructed with twelve spherical 1-3-cm diameter targets visible on MRI, but not on CT. A technical pipeline was developed, and intraoperator and interoperator reliability was tested in four operators performing a total of 96 biopsies. Statistical analysis included T1, T2, and HU repeatability using Bland-Altman analysis, Dice similarity coefficient (DSC), and intraoperator and interoperator reliability.

resultsT1, T2, and HU repeatability had 95% limits-of-agreement of 8.3%, 3.4%, and 17.9%, respectively. The phantom was highly reproducible, with DSC of 0.93 versus 0.92 for scanning the same or two different phantoms, respectively. Hit rate was 100% (96/96 targets), and all operators performed robotic biopsies using a single volumetric acquisition. The fastest procedure time was 32 min for all 12 targets.

conclusionsA reproducible biopsy phantom was developed, validated, and used to test robotic MRI/CT-fusion biopsy. The technique was highly accurate, reliable, and achievable in clinically acceptable timescales meaning it is suitable for clinical application.

Indexed as

GelatinRobotic Surgical ProceduresAgarImage-Guided BiopsyMagnetic Resonance ImagingReproducibility of ResultsTomography, X-Ray ComputedAgarGelatinImage-guided biopsyMagnetic resonance imagingMultimodal imagingPhantoms (imaging)Robotics

Identifiers

PMID36411379
PMCPMC9679095

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.