Evidence map›Paper›PMID 36570492›Full record

ArticleInternational journal of nephrology and renovascular disease2022

Lung Ultrasound Estimates the Overhydration and Benefits Blood Pressure Control in Normal or Mild Symptomatic Hemodialysis Patients.

Akeatit Trirattanapikul, Sawinee Kongpetch, Eakalak Lukkanalikitkul, Anucha Ahooja, Patamapon Seesuk, Amod Sharma, Sirirat Anutrakulchai

Abstract read
In one paragraph

Article in International journal of nephrology and renovascular disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Akeatit TrirattanapikulDepartment of Medicine, Mahidol University, Bangkok, Thailand.ORCID 0000-0002-5765-2785
Sawinee KongpetchDeparment of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Eakalak LukkanalikitkulDeparment of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Anucha AhoojaDepartment of Radiology, Khon Kaen University, Khon Kaen, Thailand.
Patamapon SeesukCenter of Excellence in Kidney Diseases, Khon Kaen University, Khon Kaen, Thailand.
Amod SharmaChronic Kidney Disease Prevention in the Northeast of Thailand (CKDNET) Project, Khon Kaen University, Khon Kaen, Thailand.ORCID 0000-0002-2860-7790
Sirirat AnutrakulchaiDeparment of Medicine, Khon Kaen University, Khon Kaen, Thailand.ORCID 0000-0002-4186-5655

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Lung ultrasound (LUS) is used for dry weight guidance by assessment of pulmonary congestion in hemodialysis (HD) patients. The aim of this study was to estimate amounts of accumulated fluid by total LUS scores (TLUSS), which were scarcely reported in HD patients who were normal or had a mild functional abnormality. In addition, the correlations between the LUS score of each area and TLUSS were determined to suggest fewer specific areas valuable to shorten the examination time of LUS. Methods: This cohort study was conducted in adult HD patients who have New York Heart Association Classes I-II. LUS and multifrequency bioimpedance (BIA) were performed at baseline and the individual prescribed dry weight was set. Then each LUS was conducted at 28 areas of bilateral intercostal spaces and calculated as TLUSS weekly for eight weeks in which dry weight was adjusted. The second BIA was also measured at week eight. The difference of pre-HD weight and target weight (weight gain; WG) represented the amount of fluid accumulation. Results: Twenty patients with a mean age of 62.2±14.0 years were enrolled. One hundred and sixty-six LUS were performed in which forty episodes of them were simultaneously measured with BIA. Optimum dry weight adjusted by TLUSS which benefited in mean reductions of blood pressure, and cardiothoracic ratios. WG amounts were significantly correlated with TLUSS (r=0.38), and with extracellular fluid (r=0.35) and overhydration fluid (r=0.39) assessed by BIA. Estimations of mean fluid overload were 2.18 (TLUSS ≤15), 2.72 (TLUSS 16-24), 3.17 (TLUSS 25-33), 3.65 (TLUSS 34-38) and 5.03 (TLUSS ≥39) in liters. The cut-off points of sum scores of 12 specific lung areas represented the none-mild were <8, moderate at 8-16, and severe pulmonary congestions were >16. Conclusion: TLUSS estimated accumulated fluid useful for volume and blood pressure controls. Performance of LUS in 12 specific lung areas may reduce spending time and support routine uses of LUS in clinical practice.

Indexed as

bioelectrical impedance analysishemodialysislung ultrasonographyvolume status

Identifiers

PMID36570492
PMCPMC9784469

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.