Evidence map›Paper›PMID 36733472›Full record

ArticleInternational journal of nephrology2023

Magnetic Resonance Visibility, Artifacts, and Overall Safety of the Self-Locating Peritoneal Dialysis Catheter with a Tungsten Tip.

Maurizio Gallieni, Umberto G Rossi, Massimo Tonolini, Andrea Ianniello, Roberta Miglio, Gianmarco Sabiu, Maurizio Cariati

Open access · goldAbstract read
In one paragraph

Article in International journal of nephrology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Maurizio GallieniNephrology and Dialysis Unit, ASST Fatebenefratelli Sacco, Milano, Italy.ORCID https://orcid.org/0000-0002-2011-2160
Umberto G RossiDepartment of Radiological Area, Interventional Radiology Unit, Galliera Hospital, Genova, Italy.ORCID https://orcid.org/0000-0001-9785-4237
Massimo TonoliniDepartment of Radiology, ASST Fatebenefratelli Sacco, Milano, Italy.
Andrea IannielloDepartment of Radiology, ASST Fatebenefratelli Sacco, Milano, Italy.
Roberta MiglioNephrology and Dialysis Unit, ASST Fatebenefratelli Sacco, Milano, Italy.
Gianmarco SabiuNephrology and Dialysis Unit, ASST Fatebenefratelli Sacco, Milano, Italy.ORCID https://orcid.org/0000-0002-9514-1652
Maurizio CariatiDiagnostic and Interventional Radiology Unit, Department of Diagnostic and Therapeutic Advanced Technology, ASST Santi Paolo and Carlo, Milano, Italy.ORCID https://orcid.org/0000-0002-2437-6702
ASST Fatebenefratelli Sacco · ITUniversity of Milan · ITBrigham and Women's Hospital · USEnte Ospedaliero Ospedali Galliera · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The self-locating peritoneal dialysis (PD) catheter, contains a tungsten tip. The effects of magnetic resonance (MR) on the catheter were evaluated, emphasizing its MR signal, artifacts, ferromagnetism, and possible heating production during the MR sequences. Methods: The catheter was studied in an ex vivo model using a 1.5T MR system and placed into a plastic box containing saline solution. Acquisitions on coronal and axial planes were obtained on fast gradient-echo T1-weighted and fast spin-echo T2-weighted. In vivo abdominal MR exams were also carried out. Results: Overall, the catheter had good visibility. In all sequences, an extensive paramagnetic blooming artifact was detected at the level of the tip tungsten ballast, with a circular artifact of 5 cm in diameter. The catheter showed no magnetic deflection, rotation, or movements during all MR sequences. After imaging, the temperature of the saline solution did not change compared to the basal measurement. Patients safely underwent abdominal MR. Conclusions: The results point to the possibility of safely performing MR in PD patients carrying the self-locating catheter. The self-locating PD catheter is stable when subjected to a 1.5T MR system. However, it creates some visual interference, preventing an accurate study of the tissues surrounding the tungsten tip.

Identifiers

PMID36733472
PMCPMC9889163
OpenAlexW4317891409

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.