ArticlePolymers2023
Development of Embroidery-Type Sensor Capable of Detecting Respiration Using the Capacitive Method.
Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Multifunctional Sensor for Strain, Pressure, and UV Light Detections Using Polyaniline and ZnO Nanostructures on a Flexible Substrate.Polymers · 2025Article
- A Wearable Strain Sensor Utilizing Shape Memory Polymer/Carbon Nanotube Composites Measuring Respiration Movements.Polymers · 2024Article
- Article
- Wearable Sensors for Respiration Monitoring: A Review.Sensors (Basel, Switzerland) · 2023Review
- Classification of Breathing Signals According to Human Motions by Combining 1D Convolutional Neural Network and Embroidered Textile Sensor.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study presents a respiration sensor that is dependent on a parallel capacitor, including connection lines and electrodes embroidered on textiles. First, characterizations of the respiration capacitor using a silver thread, including a combination of porous Eco-flex simulating air in the lungs due to respiration, were evaluated using an LCR meter. Second, the effects of air gaps on the detection of respiration motions according to the change in electrode distance under pressure were presented. The data values were measured from 1 to 300 kHz using an LCR meter and dielectric test fixture. Third, actual breathing was examined in four patterns: normal breathing, deep breathing, hyperventilation, and apnea. The test was performed after fabricating a clothing-type breathing sensor. Finally, the change in capacitance for actual respiration was determined by wearing a clothing-type respiration sensor based on the data collected. The effectiveness of the respiration sensor was demonstrated by measuring it to discern all waveforms, cycles, and ranges associated with the breathing pattern.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.