Evidence map›Paper›PMID 36819282›Full record

ArticleQuantitative imaging in medicine and surgery2023

Free-breathing simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) with isotropic resolution using 3D golden-angle radial trajectory.

Yajie Wang, Haikun Qi, Yishi Wang, Ming Xiao, Canhong Xiang, Jiahong Dong, Huijun Chen

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Clinical feasibility of accelerated whole liver water TEuropean radiology experimental · 2026
    Article
  3. Accelerated Abdominal MRI: A Review of Current Methods and Applications.Journal of magnetic resonance imaging : JMRI · 2025
    Review
  4. Observational
  5. Article
  6. Review
  7. Article
  8. Free-breathing MRI techniques for fat and RMagma (New York, N.Y.) · 2024
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yajie WangCenter for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
Haikun QiSchool of Biomedical Engineering, ShanghaiTech University, Shanghai, China.
Yishi WangPhilips Healthcare, Beijing, China.
Ming XiaoDepartment of Hepatobiliary Surgery, The Second Hospital of Shandong University, Jinan, China.
Canhong XiangHepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China.
Jiahong DongHepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China.
Huijun ChenCenter for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Conventional liver T1 mapping techniques are typically performed under breath-holding conditions; they have limited slice coverage and often rely on multiple acquisitions. Furthermore, liver fat affects the accuracy of T1 quantification. Therefore, we aim to propose a free-breathing technique for simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) in a single scan. Methods: The proposed SWALI sequence included an inversion recovery (IR) preparation pulse followed by a series of multiecho three-dimensional (3D) golden-angle radial acquisitions. For each echo time (TE), a series of images containing a mix of water and fat were reconstructed using a sliding window method. For each inversion time (TI), water and fat were separated, and then water and fat T1 estimation was conducted. The fat fraction (FF) was calculated based on the last TI image. The FF and water T1 quantification accuracy were compared with the gold standard sequences in the phantom. The Results: The mean FF and the mean water T1 values obtained by the SWALI sequence showed good agreements with chemical shift-encoded magnetic resonance imaging (CSE-MRI; r=0.998; P<0.001) and fat-suppressed (FS) IR-spin echo (SE; r=0.997; P<0.001) in the phantom. For the patients with fatty liver and the healthy volunteers, the SWALI sequence showed no significant difference with CSE-MRI in FF quantification (P=0.53). In T1 quantification, comparable T1 values were obtained with the SWALI sequence and modified Look-Locker inversion recovery (MOLLI; P=0.10) in healthy volunteers, while the water T1 estimated by the SWALI sequence was significantly lower than the water-fat compound T1 estimated by MOLLI (P<0.001) in patients with fatty liver. In the reproducibility study, the intraclass correlation coefficients (ICCs) for the estimated FF and water T1 were 0.997 and 0.943, respectively. Water T1 of the patients with HCC calculated using the SWALI sequence showed a significant reduction after the contrast administration (P<0.001). Conclusions: Free-breathing water-fat separation and T1 mapping of the whole liver with 2.5 mm isotropic spatial resolution were achieved simultaneously using the SWALI sequence in a 5-min scan.

Indexed as

fat fraction (FF)liverT1 mappingWater-fat separation

Identifiers

PMID36819282
PMCPMC9929423

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.