Evidence mapPaperPMID 36826541Full record

ArticleJournal of cardiovascular development and disease2023

Brachial Blood Pressure Invasively and Non-Invasively Obtained Using Oscillometry and Applanation Tonometry: Impact of Mean Blood Pressure Equations and Calibration Schemes on Agreement Levels.

Daniel Bia, Yanina Zócalo, Ramiro Sánchez, Juan F Torrado, Gustavo Lev, Oscar Mendiz, Franco Pessana, Agustín Ramírez, Edmundo I Cabrera-Fischer

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular development and disease, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. [Research progress in central aortic pressure estimation algorithms].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Daniel BiaDepartamento de Fisiología, Facultad de Medicina, Centro Universitario de Investigación, Innovación y Diagnóstico Arterial (CUiiDARTE), Universidad de la República, Montevideo 11800, Uruguay.
Yanina ZócaloDepartamento de Fisiología, Facultad de Medicina, Centro Universitario de Investigación, Innovación y Diagnóstico Arterial (CUiiDARTE), Universidad de la República, Montevideo 11800, Uruguay.
Ramiro SánchezMetabolic Unit and Hypertension Unit, University Hospital, Favaloro Foundation, Buenos Aires 1093, Argentina.
Juan F TorradoDepartamento de Fisiología, Facultad de Medicina, Centro Universitario de Investigación, Innovación y Diagnóstico Arterial (CUiiDARTE), Universidad de la República, Montevideo 11800, Uruguay.
Gustavo LevDepartment of Interventional Cardiology, University Hospital, Favaloro Foundation, Buenos Aires 1093, Argentina.
Oscar MendizDepartment of Interventional Cardiology, University Hospital, Favaloro Foundation, Buenos Aires 1093, Argentina.
Franco PessanaDepartment of Information Technology, Engineering and Exact Sciences Faculty, Favaloro University, Buenos Aires 1746, Argentina.
Agustín RamírezIMETTYB, Favaloro University-CONICET, Buenos Aires 1746, Argentina.
Edmundo I Cabrera-FischerIMETTYB, Favaloro University-CONICET, Buenos Aires 1746, Argentina.
Favaloro Foundation · ARComisión Sectorial de Investigación Científica · UYConsejo Nacional de Investigaciones Científicas y Técnicas · ARFavaloro University · ARUniversidad de la República · UY

Funding

Agencia Nacional de Investigación e Innovación PRSCT-008-020
6 · The paper itself

Abstract

The use of oscillometric methods to determine brachial blood pressure (bBP) can lead to a systematic underestimation of the invasively measured systolic (bSBP) and pulse (bPP) pressure levels, together with a significant overestimation of diastolic pressure (bDBP). Similarly, the agreement between brachial mean blood pressure (bMBP), invasively and non-invasively measured, can be affected by inaccurate estimations/assumptions. Despite several methodologies that can be applied to estimate bMBP non-invasively, there is no consensus on which approach leads to the most accurate estimation. Aims: to evaluate the association and agreement between: (1) non-invasive (oscillometry) and invasive bBP; (2) invasive bMBP, and bMBP (i) measured by oscillometry and (ii) calculated using six different equations; and (3) bSBP and bPP invasively and non-invasively obtained by applanation tonometry and employing different calibration methods. To this end, invasive aortic blood pressure and bBP (catheterization), and non-invasive bBP (oscillometry [Mobil-O-Graph] and brachial artery applanation tonometry [SphygmoCor]) were simultaneously obtained (34 subjects, 193 records). bMBP was calculated using different approaches. Results: (i) the agreement between invasive bBP and their respective non-invasive measurements (oscillometry) showed dependence on bBP levels (proportional error); (ii) among the different approaches used to obtain bMBP, the equation that includes a form factor equal to 33% (bMBP = bDBP + bPP/3) showed the best association with the invasive bMBP; (iii) the best approach to estimate invasive bSBP and bPP from tonometry recordings is based on the calibration scheme that employs oscillometric bMBP. On the contrary, the worst association between invasive and applanation tonometry-derived bBP levels was observed when the brachial pulse waveform was calibrated to bMBP quantified as bMBP = bDBP + bPP/3. Our study strongly emphasizes the need for methodological transparency and consensus for non-invasive bMBP assessment.

Indexed as

aortic pressureapplanation tonometrybrachial blood pressurecalibration procedureinvasive recordsmean blood pressurenon-invasive recordsoscillometrypulse waveform

Identifiers

PMID36826541
PMCPMC9959257
OpenAlexW4319843839

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.