Evidence map›Paper›PMID 37018016›Full record

ArticleJournal of applied clinical medical physics2023

Error on the stopping power ratio of ERKODENT's mouthpiece for head and neck carbon ion radiotherapy treatment.

Sung Hyun Lee, Takayuki Kanai, Hikaru Souda, Yuya Miyasaka, Hongbo Chai, Takuya Ono, Yoshifumi Yamazawa, Koji Suzuki, Azusa Sato, Masashi Katsumata and 1 more

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Sung Hyun LeeDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Takayuki KanaiDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Hikaru SoudaDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Yuya MiyasakaDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Hongbo ChaiDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Takuya OnoDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Yoshifumi YamazawaDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Koji SuzukiDepartment of Radiology, Yamagata University Hospital, Iidanishi, Yamagata, Japan.
Azusa SatoAccelerator Engineering Corporation, Inage, Chiba, Japan.
Masashi KatsumataAccelerator Engineering Corporation, Inage, Chiba, Japan.
Takeo IwaiDepartment of Heavy Particle Medical Science, Graduate School of Medical Science, Yamagata University, Iidanishi, Yamagata, Japan.
Yamagata University · JPJapan Proton Accelerator Research Complex · JPYamagata University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The errors on the stopping power ratio (SPR) of mouthpiece samples from ERKODENT were evaluated. Erkoflex and Erkoloc-pro from ERKODENT and samples that combined Erkoflex and Erkoloc-pro were computed tomography (CT)-scanned using head and neck (HN) protocol at the East Japan Heavy Ion Center (EJHIC), and the values were averaged to obtain the CT number. The integral depth dose of the Bragg curve with and without these samples was measured for 292.1, 180.9, and 118.8 MeV/u of the carbon-ion pencil beam using an ionization chamber with concentric electrodes at the horizontal port of the EJHIC. The average value of the water equivalent length (WEL) of each sample was obtained from the difference between the range of the Bragg curve and the thickness of the sample. To calculate the difference between the theoretical and measured values, the theoretical CT number and SPR value of the sample were calculated using the stoichiometric calibration method. Compared with the Hounsfield unit (HU)-SPR calibration curve used at the EJHIC, the SPR error on each measured and theoretical value was calculated. The WEL value of the mouthpiece sample had an error of approximately 3.5% in the HU-SPR calibration curve. From this error, it was evaluated that for a mouthpiece with a thickness of 10 mm, a beam range error of approximately 0.4 mm can occur, and for a mouthpiece with a thickness of 30 mm, a beam range error of approximately 1 mm can occur. For a beam passing through the mouthpiece in HN treatment, it would be practical to consider a mouthpiece margin of 1 mm to avoid beam range errors if ions pass through the mouthpiece.

Indexed as

Heavy Ion RadiotherapyProton TherapyHumansPhantoms, ImagingPolyethylenesPolyvinylsRadiotherapy Planning, Computer-AssistedWaterpolyethylene-polyvinylacetate copolymerPolyethylenesPolyvinylsWatercarbon ion radiotherapyERKODENThounsfield unitsmouthpiecestopping power ratio