Trial reportDiabetes, obesity & metabolism2023
Continuous glucose monitoring in patients with post-bariatric hypoglycaemia reduces hypoglycaemia and glycaemic variability.
Trial report in Diabetes, obesity & metabolism, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03353415 (Determining the Efficacy of Continuous Glucose Monitoring to Reduce Hypoglycemia and Improve Safety in Patients With Hypoglycemia After Gastric Surgery), which is not on this map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Determining the Efficacy of Continuous Glucose Monitoring to Reduce Hypoglycemia and Improve Safety in Patients With Hypoglycemia After Gastric Surgery
Who cites it
15 citing papers in PubMed, 22 citations in OpenAlex.
- Ring Augmentation and Pouch Resizing for the Treatment of Dumping Syndrome After Roux-en-Y Gastric Bypass: A Prospective Single-Center Trial.Obesity surgery · 2025Trial
- Post-bariatric hypoglycaemia: from altered gut physiology to targeted therapies.Endocrine connections · 2026Article
- Impact of Metabolic Surgery on Gestational Diabetes Mellitus: A Cohort Analysis.The Australian & New Zealand journal of obstetrics & gynaecology · 2026Article
- Post-bariatric Hypoglycemia Management: A Gulf Cooperation Council Consensus Statement.Journal of the Endocrine Society · 2026Article
- 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026.Diabetes care · 2026Review
- Continuous Glucose Monitoring in People at High Risk of Diabetes and Dysglycaemia: Transforming Early Risk Detection and Personalised Care.Life (Basel, Switzerland) · 2025Review
- Continuous Glucose Monitoring in Patients With Postbariatric Hypoglycemia: Effect on Hypoglycemia and Quality of Life.Journal of the Endocrine Society · 2025Article
- Alterations in intestinal bile acid transport provide a therapeutic target in patients with post-bariatric hypoglycaemia.Nature metabolism · 2025Article
- Automatic identification of unreported meals from continuous glucose monitoring data in individuals after bariatric surgery using a template matching algorithm.Scientific reports · 2025Article
- Defining Clinical Characteristics of Individuals With and Without Post-Bariatric Hypoglycemia After Gastric Bypass.Clinical endocrinology · 2025Observational
- Towards a decision support system for post bariatric hypoglycaemia: development of forecasting algorithms in unrestricted daily-life conditions.BMC medical informatics and decision making · 2025Article
- Tirzepatide Improves Early Dumping Syndrome and Glucose Nadir in Postbariatric Hypoglycemia After Sleeve Gastrectomy.JCEM case reports · 2024Article
- Society for Endocrinology guidelines for the diagnosis and management of post-bariatric hypoglycaemia.Endocrine connections · 2024Review
- Article
- Diagnosis and Management of Post-Bariatric Hypoglycemia.Journal of the American Board of Family Medicine : JABFMReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
aimTo determine whether continuous glucose monitoring (CGM) can reduce hypoglycaemia in patients with post-bariatric hypoglycaemia (PBH). MATERIALS AND
methodsIn an open-label, nonrandomized, pre-post design with sequential assignment, CGM data were collected in 22 individuals with PBH in two sequential phases: (i) masked (no access to sensor glucose or alarms); and (ii) unmasked (access to sensor glucose and alarms for low or rapidly declining sensor glucose). Twelve participants wore the Dexcom G4 device for a total of 28 days, while 10 wore the Dexcom G6 device for a total of 20 days.
resultsParticipants with PBH spent a lower percentage of time in hypoglycaemia over 24 hours with unmasked versus masked CGM (<3.3 mM/L, or <60 mg/dL: median [median absolute deviation {MAD}] 0.7 [0.8]% vs. 1.4 [1.7]%, P = 0.03; <3.9 mM/L, or <70 mg/dL: median [MAD] 2.9 [2.5]% vs. 4.7 [4.8]%; P = 0.04), with similar trends overnight. Sensor glucose data from the unmasked phase showed a greater percentage of time spent between 3.9 and 10 mM/L (70-180 mg/dL) (median [MAD] 94.8 [3.9]% vs. 90.8 [5.2]%; P = 0.004) and lower glycaemic variability over 24 hours (median [MAD] mean amplitude of glycaemic excursion 4.1 [0.98] vs. 4.4 [0.99] mM/L; P = 0.04). During the day, participants also spent a greater percentage of time in normoglycaemia with unmasked CGM (median [MAD] 94.2 [4.8]% vs. 90.9 [6.2]%; P = 0.005), largely due to a reduction in hyperglycaemia (>10 mM/L, or 180 mg/dL: median [MAD] 1.9 [2.2]% vs. 3.9 [3.6]%; P = 0.02).
conclusionsReal-time CGM data and alarms are associated with reductions in low sensor glucose, elevated sensor glucose, and glycaemic variability. This suggests CGM allows patients to detect hyperglycaemic peaks and imminent hypoglycaemia, allowing dietary modification and self-treatment to reduce hypoglycaemia. The use of CGM devices may improve safety in PBH, particularly for patients with hypoglycaemia unawareness.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.