Evidence map›Paper›PMID 37050693›Full record

ArticleSensors (Basel, Switzerland)2023

Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction.

Hongbae Jeong, Georgios Ntolkeras, Tracy Warbrick, Manfred Jaschke, Rajiv Gupta, Michael H Lev, Jurriaan M Peters, Patricia Ellen Grant, Giorgio Bonmassar

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Hongbae JeongAA. Martinos Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA.ORCID 0000-0003-4908-2070
Georgios NtolkerasDepartment of Newborn Medicine, Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children's Hospital, Boston, MA 02115, USA.ORCID 0000-0002-2281-035X
Tracy WarbrickBrain Products GmbH, 82205 Gilching, Germany.
Manfred JaschkeBrain Products GmbH, 82205 Gilching, Germany.
Rajiv GuptaDepartment of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
Michael H LevDepartment of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
Jurriaan M PetersDepartment of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.ORCID 0000-0002-6725-2814
Patricia Ellen GrantDepartment of Newborn Medicine, Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children's Hospital, Boston, MA 02115, USA.ORCID 0000-0003-1005-4013
Giorgio BonmassarAA. Martinos Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA.ORCID 0000-0002-4694-9698
Boston Children's Hospital · USHarvard University · USBrain (Germany) · DE

Funding

Genetic Analysis and Manipulation Core (GAEC)P50HD105351 · NICHD · BOSTON CHILDREN'S HOSPITAL · PI Hisashi Umemori · 2021 to 2026
$9.4M
Dense Array Image compatible EEG for enhanced neonatal careR01EB024343 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI BONMASSAR, GIORGIO · 2017 to 2020
$2.9M
NIBIB NIH HHS R01 EB024343NICHD NIH HHS P50 HD105351NIH HHS R01EB024343
6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) and continuous electroencephalogram (EEG) monitoring are essential in the clinical management of neonatal seizures. EEG electrodes, however, can significantly degrade the image quality of both MRI and CT due to substantial metallic artifacts and distortions. Thus, we developed a novel thin film trace EEG net ("NeoNet") for improved MRI and CT image quality without compromising the EEG signal quality. The aluminum thin film traces were fabricated with an ultra-high-aspect ratio (up to 17,000:1, with dimensions 30 nm × 50.8 cm × 100 µm), resulting in a low density for reducing CT artifacts and a low conductivity for reducing MRI artifacts. We also used numerical simulation to investigate the effects of EEG nets on the B

Indexed as

AluminumArtifactsAdultChildElectroencephalographyHumansInfant, NewbornMagnetic Resonance ImagingTomography, X-Ray ComputedAluminumantenna effectB1 artifactRF-induced currentsstreak artifact

Identifiers

PMID37050693
PMCPMC10098641
OpenAlexW4362519858

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked