Evidence map›Paper›PMID 37092739›Full record

ArticleJournal of applied clinical medical physics2023

Improving synthetic CT accuracy by combining the benefits of multiple normalized preprocesses.

Zheng Cao, Xiang Gao, Yankui Chang, Gongfa Liu, Yuanji Pei

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. [Methods for enhancing image quality of soft tissue regions in synthetic CT based on cone-beam CT].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zheng CaoNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China.ORCID https://orcid.org/0000-0003-2249-5705
Xiang GaoHematology & Oncology Department, Hefei First People's Hospital, Hefei, China.
Yankui ChangSchool of Nuclear Science and Technology, University of Science and Technology of China, Hefei, China.
Gongfa LiuNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China.
Yuanji PeiNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China.

Funding

Hefei Municipal Health Commission (CN) Applied Medicine Research Project hwk2018zd012
6 · The paper itself

Abstract

purposeTo investigate the effect of different normalization preprocesses in deep learning on the accuracy of different tissues in synthetic computed tomography (sCT) and to combine their advantages to improve the accuracy of all tissues.

methodsThe cycle-consistent adversarial network (CycleGAN) model was used to generate sCT images from megavolt cone-beam CT (MVCBCT) images. In this study, 2639 head MVCBCT and CT image pairs from 203 patients were collected as a training set, and 249 image pairs from 29 patients were collected as a test set. We normalized the voxel values in images to 0 to 1 or -1 to 1, using two linear and five nonlinear normalization preprocessing methods to obtain seven data sets and compared the accuracy of different tissues in different sCT obtained from training these data. Finally, to combine the advantages of different normalization preprocessing methods, we obtained sCT_Blur by cropping, stitching, and smoothing (OpenCV's cv2.medianBlur, kernel size 5) each group of sCTs and evaluated its image quality and accuracy of OARs.

resultsDifferent normalization preprocesses made sCT more accurate in different tissues. The proposed sCT_Blur took advantage of multiple normalization preprocessing methods, and all tissues are more accurate than the sCT obtained using a single conventional normalization method. Compared with other sCT images, the structural similarity of sCT_Blur versus CT was improved to 0.906 ± 0.019. The mean absolute errors of the CT numbers were reduced to 15.7 ± 4.1 HU, 23.2 ± 7.1 HU, 11.5 ± 4.1 HU, 212.8 ± 104.6 HU, 219.4 ± 35.1 HU, and 268.8 ± 88.8 HU for the oral cavity, parotid, spinal cord, cavity, mandible, and teeth, respectively.

conclusionThe proposed approach combined the advantages of several normalization preprocessing methods to improve the accuracy of all tissues in sCT images, which is promising for improving the accuracy of dose calculations based on CBCT images in adaptive radiotherapy.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedCone-Beam Computed TomographyHeadHumansRadiotherapy DosageRadiotherapy Planning, Computer-Assistedadaptive radiotherapyCBCTcycleGANnormalization preprocessing methodsynthetic CT

Identifiers

PMID37092739
PMCPMC10402686

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.