Evidence map›Paper›PMID 37109088›Full record

ArticleJournal of clinical medicine2023

Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study.

Thomas Muders, Benjamin Hentze, Steffen Leonhardt, Christian Putensen

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
5.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Electrical Impedance Tomography: The Electrocardiogram for the Lungs?American journal of respiratory and critical care medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Thomas MudersDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany.ORCID 0000-0001-7596-4427
Benjamin HentzeDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany.ORCID 0000-0003-1071-1861
Steffen LeonhardtChair for Medical Information Technology, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-6898-6887
Christian PutensenDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany.
University Hospital Bonn · DERWTH Aachen University · DE

Funding

Deutsche Forschungsgemeinschaft PU 219/2-1 and PU 219/2-3
6 · The paper itself

Abstract

Monitoring regional blood flow distribution in the lungs appears to be useful for individually optimizing ventilation therapy. Electrical impedance tomography (EIT) can be used at the bedside for indicator-based regional lung perfusion measurement. Hypertonic saline is widely used as a contrast agent but could be problematic for clinical use due to potential side effects. In five ventilated healthy pigs, we investigated the suitability of five different injectable and clinically approved solutions as contrast agents for EIT-based lung perfusion measurement. Signal extraction success rate, signal strength, and image quality were analyzed after repeated 10 mL bolus injections during temporary apnea. The best results were obtained using NaCl 5.85% and sodium-bicarbonate 8.4% with optimal success rates (100%, each), the highest signal strengths (100 ± 25% and 64 ± 17%), and image qualities (r = 0.98 ± 0.02 and 0.95 ± 0.07). Iomeprol 400 mg/mL (non-ionic iodinated X-ray contrast medium) and Glucose 5% (non-ionic glucose solution) resulted in mostly well usable signals with above average success rates (87% and 89%), acceptable signal strength (32 ± 8% and 16 + 3%), and sufficient image qualities (r = 0.80 ± 0.19 and 0.72 ± 0.21). Isotonic balanced crystalloid solution failed due to a poor success rate (42%), low signal strength (10 ± 4%), and image quality (r = 0.43 ± 0.28). While Iomeprol might enable simultaneous EIT and X-ray measurements, glucose might help to avoid sodium and chloride overload. Further research should address optimal doses to balance reliability and potential side effects.

Indexed as

bedside monitoringbedside visualizationcontrast agentelectrical impedance tomographyfunctional imagingindividualized therapypulmonary perfusion

Identifiers

PMID37109088
PMCPMC10143707
OpenAlexW4362698836

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked