Evidence map›Paper›PMID 37112309›Full record

ArticleSensors (Basel, Switzerland)2023

Evaluation of In-Cloth versus On-Skin Sensors for Measuring Trunk and Upper Arm Postures and Movements.

Damien Hoareau, Xuelong Fan, Farhad Abtahi, Liyun Yang

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Damien HoareauDepartment of Mechatronics, École Normale Supérieure de Rennes, 35170 Bruz, France.ORCID 0000-0002-5725-383X
Xuelong FanInstitute of Environmental Medicine, Karolinska Institutet, Solnavägen 4, SE-171 77 Stockholm, Sweden.ORCID 0000-0003-4145-5717
Farhad AbtahiDivision of Ergonomics, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57 Huddinge, Sweden.ORCID 0000-0001-7807-8682
Liyun YangInstitute of Environmental Medicine, Karolinska Institutet, Solnavägen 4, SE-171 77 Stockholm, Sweden.ORCID 0000-0001-7285-824X
Karolinska Institutet · SECentre National de la Recherche Scientifique · FRKarolinska University Hospital · SE

Funding

AFA Insurance (Sweden) 180098AFA Insurance (Sweden) 180254Erasmus+ AC131-SMT-2022
6 · The paper itself

Abstract

Smart workwear systems with embedded inertial measurement unit sensors are developed for convenient ergonomic risk assessment of occupational activities. However, its measurement accuracy can be affected by potential cloth artifacts, which have not been previously assessed. Therefore, it is crucial to evaluate the accuracy of sensors placed in the workwear systems for research and practice purposes. This study aimed to compare in-cloth and on-skin sensors for assessing upper arms and trunk postures and movements, with the on-skin sensors as the reference. Five simulated work tasks were performed by twelve subjects (seven women and five men). Results showed that the mean (±SD) absolute cloth-skin sensor differences of the median dominant arm elevation angle ranged between 1.2° (±1.4) and 4.1° (±3.5). For the median trunk flexion angle, the mean absolute cloth-skin sensor differences ranged between 2.7° (±1.7) and 3.7° (±3.9). Larger errors were observed for the 90th and 95th percentiles of inclination angles and inclination velocities. The performance depended on the tasks and was affected by individual factors, such as the fit of the clothes. Potential error compensation algorithms need to be investigated in future work. In conclusion, in-cloth sensors showed acceptable accuracy for measuring upper arm and trunk postures and movements on a group level. Considering the balance of accuracy, comfort, and usability, such a system can potentially be a practical tool for ergonomic assessment for researchers and practitioners.

Indexed as

ArmMovementBiomechanical PhenomenaFemaleHumansMalePostureUpper Extremityaccuracyinertial measurement unitsmusculoskeletal disordersphysical ergonomicsrisk assessmentsmart workwear systemswearable sensors

Identifiers

PMID37112309
PMCPMC10142577
OpenAlexW4365513598

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.