Evidence map›Paper›PMID 37206136›Full record

ArticleBiomedical optics express2023

Label-free multiplex sensing from buffer and immunoglobulin G sensing from whole blood with photonic crystal slabs using angle-tuning of an optical interference filter.

Fabio A Kraft, Holger Baur, Moritz Bommer, Andreas Latz, Stefanie Fitschen-Oestern, Sabine Fuchs, Martina Gerken

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Fabio A KraftIntegrated Systems and Photonics, Faculty of Engineering, Kiel University, Germany.ORCID https://orcid.org/0000-0001-5340-1842
Holger BaurCMO-SYS GmbH, Göppingen, Germany.
Moritz BommerCMO-SYS GmbH, Göppingen, Germany.
Andreas LatzIntegrated Systems and Photonics, Faculty of Engineering, Kiel University, Germany.
Stefanie Fitschen-OesternUniversity Hospital Schleswig-Holstein, Kiel University, Germany.
Sabine FuchsKiel Nano, Surface and Interface Science KiNSIS, Kiel University, Germany.
Martina GerkenIntegrated Systems and Photonics, Faculty of Engineering, Kiel University, Germany.ORCID https://orcid.org/0000-0002-4234-7833
Christian-Albrechts-Universität zu Kiel · DEApplied Photonics (United Kingdom) · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Direct detection of biomarkers from unpurified whole blood has been a challenge for label-free detection platforms, such as photonic crystal slabs (PCS). A wide range of measurement concepts for PCS exist, but exhibit technical limitations, which render them unsuitable for label-free biosensing with unfiltered whole blood. In this work, we single out the requirements for a label-free point-of-care setup based on PCS and present a wavelength selecting concept by angle tuning of an optical interference filter, which fulfills these requirements. We investigate the limit of detection (LOD) for bulk refractive index changes and obtain a value of 3.4 E-4 refractive index units (RIU). We demonstrate label-free multiplex detection for different types of immobilization entities, including aptamers, antigens, and simple proteins. For this multiplex setup we detect thrombin at a concentration of 6.3 µg/ml, antibodies of glutathione S-transferase (GST) diluted by a factor of 250, and streptavidin at a concentration of 33 µg/ml. In a first proof of principle experiment, we demonstrate the ability to detect immunoglobulins G (IgG) from unfiltered whole blood. These experiments are conducted directly in the hospital without temperature control of the photonic crystal transducer surface or the blood sample. We set the detected concentration levels into a medical frame of reference and point out possible applications.

Identifiers

PMID37206136
PMCPMC10191658
OpenAlexW4366526447

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.