Evidence map›Paper›PMID 37297821›Full record

ReviewJournal of clinical medicine2023

Dual Source Photon-Counting Computed Tomography-Part II: Clinical Overview of Neurovascular Applications.

Filippo Cademartiri, Antonella Meloni, Laura Pistoia, Giulia Degiorgi, Alberto Clemente, Carmelo De Gori, Vincenzo Positano, Simona Celi, Sergio Berti, Michele Emdin and 9 more

Abstract readReview
In one paragraph

Review in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Photon-Counting CT for Evaluation of Coiled Intracranial Aneurysms.AJNR. American journal of neuroradiology · 2026
    Article
  3. Article
  4. Clinical application of cardiac computed tomography in cardiomyopathy.The international journal of cardiovascular imaging · 2026
    Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors.

Filippo CademartiriDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.ORCID 0000-0002-0579-3279
Antonella MeloniDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.ORCID 0000-0002-2284-8585
Laura PistoiaDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.ORCID 0000-0002-5319-2769
Giulia DegiorgiDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.
Alberto ClementeDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.ORCID 0000-0002-4285-9468
Carmelo De GoriDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.
Vincenzo PositanoDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.ORCID 0000-0001-6955-9572
Simona CeliBioCardioLab, Department of Bioengineering, Fondazione Monasterio/CNR, 54100 Massa, Italy.
Sergio BertiCardiology Unit, Ospedale del Cuore, Fondazione Monasterio/CNR, 54100 Massa, Italy.ORCID 0000-0002-5244-0556
Michele EmdinDepartment of Cardiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.
Daniele PanettaInstitute of Clinical Physiology, National Council of Research, 56124 Pisa, Italy.ORCID 0000-0002-4184-0175
Luca MenichettiInstitute of Clinical Physiology, National Council of Research, 56124 Pisa, Italy.ORCID 0000-0002-3293-9616
Bruna PunzoDepartment of Radiology, IRCCS SynLab-SDN, 80131 Naples, Italy.
Carlo CavaliereDepartment of Radiology, IRCCS SynLab-SDN, 80131 Naples, Italy.
Eduardo BossoneDepartment of Cardiology, Ospedale Cardarelli, 80131 Naples, Italy.ORCID 0000-0003-2769-9950
Luca SabaDepartment of Radiology, University Hospital, 09042 Monserrato, Italy.
Riccardo CauDepartment of Radiology, University Hospital, 09042 Monserrato, Italy.ORCID 0000-0002-7910-1087
Ludovico La GruttaDepartment of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties-ProMISE, Department of Radiology, University Hospital "P. Giaccone", 90127 Palermo, Italy.
Erica MaffeiDepartment of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography-PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and material decomposition. In this overview of the existing literature on PCCT, we describe the physical principles, the advantages and the disadvantages of conventional energy integrating detectors and PCDs, and finally, we discuss the applications of the PCD, focusing specifically on its implementation in the neurovascular field.

Indexed as

computed tomography angiographyenergy integrating detectorneurovascularphoton-counting computed tomographyphoton-counting detector

Identifiers

PMID37297821
PMCPMC10253695

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.