Evidence map›Paper›PMID 37368113›Full record

ArticleEuropean radiology2023

Real-time, acquisition parameter-free voxel-wise patient-specific Monte Carlo dose reconstruction in whole-body CT scanning using deep neural networks.

Yazdan Salimi, Azadeh Akhavanallaf, Zahra Mansouri, Isaac Shiri, Habib Zaidi

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 3 countries.

Yazdan SalimiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland.
Azadeh AkhavanallafDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland.
Zahra MansouriDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland.
Isaac ShiriDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland.
Habib ZaidiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva, Switzerland. habib.zaidi@hcuge.ch.ORCID http://orcid.org/0000-0001-7559-5297
University Hospital of Geneva · CHUniversity of Geneva · CH

Funding

European Commission Euratom researchEuropean Commission training programme 2019-2020 Sinfonia project under grant agreement No 945196
6 · The paper itself

Abstract

objectiveWe propose a deep learning-guided approach to generate voxel-based absorbed dose maps from whole-body CT acquisitions.

methodsThe voxel-wise dose maps corresponding to each source position/angle were calculated using Monte Carlo (MC) simulations considering patient- and scanner-specific characteristics (SP_MC). The dose distribution in a uniform cylinder was computed through MC calculations (SP_uniform). The density map and SP_uniform dose maps were fed into a residual deep neural network (DNN) to predict SP_MC through an image regression task. The whole-body dose maps reconstructed by the DNN and MC were compared in the 11 test cases scanned with two tube voltages through transfer learning with/without tube current modulation (TCM). The voxel-wise and organ-wise dose evaluations, such as mean error (ME, mGy), mean absolute error (MAE, mGy), relative error (RE, %), and relative absolute error (RAE, %), were performed.

resultsThe model performance for the 120 kVp and TCM test set in terms of ME, MAE, RE, and RAE voxel-wise parameters was  - 0.0302 ± 0.0244 mGy, 0.0854 ± 0.0279 mGy,  - 1.13 ± 1.41%, and 7.17 ± 0.44%, respectively. The organ-wise errors for 120 kVp and TCM scenario averaged over all segmented organs in terms of ME, MAE, RE, and RAE were  - 0.144 ± 0.342 mGy, and 0.23 ± 0.28 mGy,  - 1.11 ± 2.90%, 2.34 ± 2.03%, respectively.

conclusionOur proposed deep learning model is able to generate voxel-level dose maps from a whole-body CT scan with reasonable accuracy suitable for organ-level absorbed dose estimation. CLINICAL RELEVANCE STATEMENT: We proposed a novel method for voxel dose map calculation using deep neural networks. This work is clinically relevant since accurate dose calculation for patients can be carried out within acceptable computational time compared to lengthy Monte Carlo calculations. KEY POINTS: • We proposed a deep neural network approach as an alternative to Monte Carlo dose calculation. • Our proposed deep learning model is able to generate voxel-level dose maps from a whole-body CT scan with reasonable accuracy, suitable for organ-level dose estimation. • By generating a dose distribution from a single source position, our model can generate accurate and personalized dose maps for a wide range of acquisition parameters.

Indexed as

Neural Networks, ComputerWhole Body ImagingHumansMonte Carlo MethodPhantoms, ImagingRadiation DosageTomography, X-Ray ComputedComputed tomographyDeep learningMonte Carlo methodNeural networks

Identifiers

PMID37368113
PMCPMC10667156
OpenAlexW4382181921

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked