Evidence map›Paper›PMID 37370589›Full record

ArticleBioengineering (Basel, Switzerland)2023

Neonatal Seizure Detection Using a Wearable Multi-Sensor System.

Hongyu Chen, Zaihao Wang, Chunmei Lu, Feng Shu, Chen Chen, Laishuan Wang, Wei Chen

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Hongyu ChenGreater Bay Area Institute of Precision Medicine, Guangzhou 511466, China.ORCID 0000-0003-4317-7554
Zaihao WangSchool of Information Science and Technology, Fudan University, Shanghai 200438, China.
Chunmei LuNational Health Commission Key Laboratory of Neonatal Diseases, Department of Neonatology, Children's Hospital of Fudan University, Shanghai 200433, China.
Feng ShuCollaborative Innovation Center of Polymers and Polymer Composites, Department of Macromolecular Science, Fudan University, Shanghai 201203, China.
Chen ChenSchool of Information Science and Technology, Fudan University, Shanghai 200438, China.
Laishuan WangNational Health Commission Key Laboratory of Neonatal Diseases, Department of Neonatology, Children's Hospital of Fudan University, Shanghai 200433, China.
Wei ChenSchool of Information Science and Technology, Fudan University, Shanghai 200438, China.
Fudan University · CNChildren's Hospital of Fudan University · CN

Funding

Greater Bay Area Research Institute of Precision Medicine (Guangzhou) P1006
6 · The paper itself

Abstract

Neonatal seizure is an important clinical symptom of brain dysfunction, which is more common in infancy than in childhood. At present, video electroencephalogram (VEEG) technology is widely used in clinical practice. However, video electroencephalogram technology has several disadvantages. For example, the wires connecting the medical instruments may interfere with the infant's movement and the gel patch electrode or disk electrode commonly used to monitor EEG may cause skin allergies or even tears. For the above reasons, we developed a wearable multi-sensor platform for newborns to collect physiological and movement signals. In this study, we designed a second-generation multi-sensor platform and developed an automatic detection algorithm for neonatal seizures based on ECG, respiration and acceleration. Data for 38 neonates were recorded at the Children's Hospital of Fudan University in Shanghai. The total recording time was approximately 300 h. Four of the patients had seizures during data collection. The total recording time for the four patients was approximately 34 h, with 30 seizure episodes recorded. These data were evaluated by the algorithm. To evaluate the effectiveness of combining ECG, respiration and movement, we compared the performance of three types of seizure detectors. The first detector included features from ECG, respiration and acceleration records; the second detector incorporated features based on respiratory movement from respiration and acceleration records; and the third detector used only ECG-based features from ECG records. Our study illustrated that, compared with the detector utilizing individual modal features, multi-modal feature detectors could achieve favorable overall performance, reduce false alarm rates and give higher F-measures.

Indexed as

muti-sensor platformneonatal seizureseizure detectionwearable sensor

Identifiers

PMID37370589
PMCPMC10294985
OpenAlexW4378715000

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.