Evidence map›Paper›PMID 37415339›Full record

ArticleMagnetic resonance in medicine2023

Realistic numerical simulations of diffusion tensor cardiovascular magnetic resonance: The effects of perfusion and membrane permeability.

Ignasi Alemany, Jan N Rose, Pedro F Ferreira, Dudley J Pennell, Sonia Nielles-Vallespin, Andrew D Scott, Denis J Doorly

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Simultaneous non-contrast assessment of cardiac microstructure and perfusion in vivo in the human heart.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Ignasi AlemanyDepartment of Aeronautics, Imperial College London, London, UK.ORCID 0000-0002-3613-3660
Jan N RoseDepartment of Aeronautics, Imperial College London, London, UK.ORCID 0000-0002-2273-7439
Pedro F FerreiraCardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK.ORCID 0000-0002-0436-3496
Dudley J PennellCardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK.ORCID 0000-0001-5523-1314
Sonia Nielles-VallespinCardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK.ORCID 0000-0003-0412-2796
Andrew D ScottCardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK.ORCID 0000-0001-7656-3123
Denis J DoorlyDepartment of Aeronautics, Imperial College London, London, UK.ORCID 0000-0002-5372-4702
Guy's and St Thomas' NHS Foundation Trust · GBImperial College London · GB

Funding

British Heart Foundation RE/13/4/30184British Heart Foundation RG/19/1/34160
6 · The paper itself

Abstract

purposeTo study the sensitivity of diffusion tensor cardiovascular magnetic resonance (DT-CMR) to microvascular perfusion and changes in cell permeability.

methodsMonte Carlo (MC) random walk simulations in the myocardium have been performed to simulate self-diffusion of water molecules in histology-based media with varying extracellular volume fraction (ECV) and permeable membranes. The effect of microvascular perfusion on simulations of the DT-CMR signal has been incorporated by adding the contribution of particles traveling through an anisotropic capillary network to the diffusion signal. The simulations have been performed considering three pulse sequences with clinical gradient strengths: monopolar stimulated echo acquisition mode (STEAM), monopolar pulsed-gradient spin echo (PGSE), and second-order motion-compensated spin echo (MCSE).

resultsReducing ECV intensifies the diffusion restriction and incorporating membrane permeability reduces the anisotropy of the diffusion tensor. Widening the intercapillary velocity distribution results in increased measured diffusion along the cardiomyocytes long axis when the capillary networks are anisotropic. Perfusion amplifies the mean diffusivity for STEAM while the opposite is observed for short diffusion encoding time sequences (PGSE and MCSE).

conclusionThe effect of perfusion on the measured diffusion tensor is reduced using an increased reference b-value. Our results pave the way for characterization of the response of DT-CMR to microstructural changes underlying cardiac pathology and highlight the higher sensitivity of STEAM to permeability and microvascular circulation due to its longer diffusion encoding time.

Indexed as

Diffusion Tensor ImagingMyocardiumDiffusion Magnetic Resonance ImagingMagnetic Resonance SpectroscopyMyocytes, CardiacPerfusionDT-CMRmodelingMonte Carloperfusion

Identifiers

PMID37415339
PMCPMC10952789
OpenAlexW4383480990

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.