Evidence map›Paper›PMID 37419693›Full record

Trial reportJournal of neurointerventional surgery2024

Neqstent coil-assisted flow diverter (NQS) for the treatment of bifurcation aneurysms: the coil-assisted flow diversion safety and performance study (CAFI).

Thomas Liebig, Gyula Gal, Cian O Kelly, Fritz Wodarg, Monika Killer-Oberpfalzer, Yigit Ozpeynirci, Maxim Bester, Ioannis Tsogkas, Marios-Nikos Psychogios, Olav Jansen and 1 more

Registry-linked trialAbstract readMulticenter StudyClinical Trial
In one paragraph

Trial report in Journal of neurointerventional surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04187573 (Coil Assisted Flow Diversion), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04187573 nacompletednot on this map

Coil Assisted Flow Diversion: A Prospective, Single Arm, Multi-center Study to Assess the Safety and Performance of Neqstent in Adjunctive Therapy (CAFI Study)

TypeinterventionalSponsorCerus Endovascular, Inc.Ran2020 to 2023Enrolled38ConditionsIntracranial AneurysmArmsNeqstent
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Thomas LiebigDepartment of Neuroradiology, Ludwig Maximilian University, Muenchen, Germany thomas.liebig@me.com.ORCID http://orcid.org/0000-0001-5640-7780
Gyula GalDepartment of Radiology, Odense Universitetshospital, Odense, Denmark.ORCID http://orcid.org/0000-0002-9575-4109
Cian O KellyDepartment of Surgery (Neurosurgery), University of Alberta, Edmonton, Alberta, Canada.
Fritz WodargDepartment of Radiology and Neuroradiology, Universitaetsklinikum Schleswig-Holstein Campus Kiel, Kiel, Germany.ORCID http://orcid.org/0000-0003-1413-2699
Monika Killer-OberpfalzerNeurology/Research Institute of Neurointervention, Paracelsus Medical University, Salzburg, Austria.ORCID http://orcid.org/0000-0001-5572-7694
Yigit OzpeynirciDepartment of Neuroradiology, Ludwig Maximilian University, Muenchen, Germany.
Maxim BesterDepartment of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Ioannis TsogkasDepartment of Neuroradiology, University Hospital Basel, Basel, Switzerland.
Marios-Nikos PsychogiosDepartment of Neuroradiology, University Hospital Basel, Basel, Switzerland.
Olav JansenDepartment of Radiology and Neuroradiology, Universitaetsklinikum Schleswig-Holstein Campus Kiel, Kiel, Germany.
Jens FiehlerDepartment of Neuroradiology, University Medical Center Hamburg Eppendorf, Hamburg, Germany.ORCID http://orcid.org/0000-0001-8533-7478

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundThe Neqstent coil-assisted flow diverter (NQS) is a neck bridging device to facilitate coil occlusion of intracranial aneurysms. CAFI is a prospective, single-arm, multicenter study on the safety and performance of the NQS adjunctive therapy device together with platinum coils for treatment of unruptured intracranial aneurysms.

methodsThirty-eight patients were enrolled. Primary endpoints were occlusion at 6 months for efficacy, and any major stroke or non-accidental death up to 30 days or major disabling stroke within 6 months for safety. Secondary endpoints were re-treatment rate, procedure time, and procedure/device-related adverse events. Procedural and follow-up imaging was reviewed by an independent core laboratory. Adverse events were reviewed and adjudicated by a clinical events committee.

resultsThe NQS was successfully implanted in 36/38 aneurysms, 2/38 in the intention-to-treat group did not receive a NQS and were excluded from follow-up after 30 days. In the per protocol group (PP), 33/36 patients were available for angiographic follow-up. Device related adverse events were recorded in 4/38 (10.5%) patients, one hemorrhagic and three thromboembolic. In the PP group, immediate post-treatment adequate occlusion (RR1 and RR2) was seen in 9/36 (25%) and progressed to 28/36 (77.8%) at 6 months. Complete occlusion (RR1) was achieved in 29/36 (80.6%) at the last available angiogram (3/36 were post procedure). The mean procedure time was 129 min (50-300 min, median 120 min).

conclusionThe NQS in conjunction with coils appears to be effective in the treatment of intracranial wide-neck bifurcation aneurysms, but its safety remains to be proved in larger series. TRIAL REGISTRATION NUMBER: NCT04187573.

Indexed as

Intracranial AneurysmAdultAgedEmbolization, TherapeuticEndovascular ProceduresFemaleFollow-Up StudiesHumansMaleMiddle AgedProspective StudiesStentsTreatment Outcomeaneurysmbifurcationcoilsendovascularflow diversionintrasaccularNQS

Identifiers

PMID37419693
PMCPMC11228220

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.