Validation of the GlutenTox® ELISA Rapid G12 Test Kit for Determination of Gluten in Select Non-Heat-Processed Matrixes and Heat-Processed Matrixes: AOAC Performance Tested MethodSM 042301.

Carlos Galera, Claudia Salagre, Ana López

Open access · hybridAbstract read
In one paragraph

Article in Journal of AOAC International, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Carlos GaleraQuality Department, Hygiena Diagnóstica España, S.L.U, Calle Cañada Real 31-35, P.I. Parque Plata, Camas (Sevilla), 41900, España.ORCID 0000-0002-2504-0346
Claudia SalagreQuality Department, Hygiena Diagnóstica España, S.L.U, Calle Cañada Real 31-35, P.I. Parque Plata, Camas (Sevilla), 41900, España.ORCID 0000-0002-6464-5313
Ana LópezQuality Department, Hygiena Diagnóstica España, S.L.U, Calle Cañada Real 31-35, P.I. Parque Plata, Camas (Sevilla), 41900, España.ORCID 0000-0003-2601-0445

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe GlutenTox® ELISA Rapid G12 test kit is a quantitative method designed for the determination of the immunotoxic fraction of gluten in food samples.

objectiveTo obtain AOAC Performance-Tested MethodsSM certification for the method for the detection and quantification of gluten from wheat, barley, and rye flours in select foods (non-heat-processed) and incurred (heat-processed) matrixes.

methodsThe method was evaluated following the Guidelines for Validation of Quantitative Gluten Methods, with Specific Examples for ELISA Assays. The validation study was conducted at Hygiena Diagnóstica España using five food matrixes (soy flour, corn bread, seasoning mix, rolled oats, and evaporated milk) artificially contaminated with gluten from wheat, barley, or rye flour at different concentrations: 0, 5, 10, and 20 mg/kg. For each matrix and gluten contamination level, five or six individually extracted test portions were analyzed. A second bread matrix was prepared by baking a gluten-free bread mix spiked at 0, 20, and 30 mg/kg gluten from wheat, barley, or rye flour for incurred matrix testing. Ten individually extracted test portions were tested for each incurred bread and contamination level of gluten.

resultsThe method met the AOAC performance requirements for detection and quantification of wheat gluten in the selected food matrixes, incurred bread sample, and spike levels of wheat gluten, showing an acceptable recovery. When tested with barley and rye flours, most of the results showed acceptable recoveries or a slight overestimation, depending on the matrix and gluten concentration. Method developer and independent laboratory results were comparable.

conclusionsThe validation study demonstrated that the test kit is a reliable, accurate, quick, and easy-to-use method for the detection and quantification of gluten concentration in food and incurred matrixes from wheat, barley, and rye flours. HIGHLIGHTS: Most reagents provided in the kit are at ready-to-use concentrations.

Indexed as

GlutensHordeumBreadEnzyme-Linked Immunosorbent AssayFlourHot TemperatureTriticumGlutens