Evidence map›Paper›PMID 37568913›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Fuzzy Logic-Based System for Identifying the Severity of Diabetic Macular Edema from OCT B-Scan Images Using DRIL, HRF, and Cystoids.

Aditya Tripathi, Preetham Kumar, Akshat Tulsani, Pavithra Kodiyalbail Chakrapani, Geetha Maiya, Sulatha V Bhandary, Veena Mayya, Sameena Pathan, Raghavendra Achar, U Rajendra Acharya

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Aditya TripathiDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.
Preetham KumarDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.ORCID 0000-0002-0736-7687
Akshat TulsaniDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.ORCID 0000-0001-8321-7675
Pavithra Kodiyalbail ChakrapaniDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.ORCID 0000-0002-7086-394X
Geetha MaiyaDepartment of Computer Science and Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.
Sulatha V BhandaryDepartment of Ophthalmology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal 576104, India.
Veena MayyaDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.ORCID 0000-0002-8091-5053
Sameena PathanDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.ORCID 0000-0002-9867-4382
Raghavendra AcharDepartment of Information & Communication Technology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India.
U Rajendra AcharyaSchool of Mathematics, Physics and Computing, University of Southern Queensland, Springfield Central, QLD 4300, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Diabetic Macular Edema (DME) is a severe ocular complication commonly found in patients with diabetes. The condition can precipitate a significant drop in VA and, in extreme cases, may result in irreversible vision loss. Optical Coherence Tomography (OCT), a technique that yields high-resolution retinal images, is often employed by clinicians to assess the extent of DME in patients. However, the manual interpretation of OCT B-scan images for DME identification and severity grading can be error-prone, with false negatives potentially resulting in serious repercussions. In this paper, we investigate an Artificial Intelligence (AI) driven system that offers an end-to-end automated model, designed to accurately determine DME severity using OCT B-Scan images. This model operates by extracting specific biomarkers such as Disorganization of Retinal Inner Layers (DRIL), Hyper Reflective Foci (HRF), and cystoids from the OCT image, which are then utilized to ascertain DME severity. The rules guiding the fuzzy logic engine are derived from contemporary research in the field of DME and its association with various biomarkers evident in the OCT image. The proposed model demonstrates high efficacy, identifying images with DRIL with 93.3% accuracy and successfully segmenting HRF and cystoids from OCT images with dice similarity coefficients of 91.30% and 95.07% respectively. This study presents a comprehensive system capable of accurately grading DME severity using OCT B-scan images, serving as a potentially invaluable tool in the clinical assessment and treatment of DME.

Indexed as

clinical decision support systemcomputer visionDMEfuzzy enginehealthcareimage classificationsemantic segmentation

Identifiers

PMID37568913
PMCPMC10416860

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked