SynthesisScientific reports2023
Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis.
Synthesis in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.
- Pooled it
- Human-machine co-adaptation to automated insulin delivery: a randomised clinical trial using digital twin technology.NPJ digital medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This meta-analysis compares the efficacy and safety of Closed-Loop Control (CLC) to Sensor-Augmented Insulin Pump (SAP) for adolescent patients with Type 1 Diabetes Mellitus (T1DM). Eleven randomized-controlled trials were included with a total of 570 patients, from a total of 869 articles found adhering to PRISMA guidelines. The efficacy of the therapies were evaluated from the day, night and during physical activities monitoring of the of the mean blood glucose (BG), Time In Range (TIR), and Standard Deviation (SD) of the glucose variability. The safety measure of the therapies, was assessed from the day and night recording of the hypoglycemic and hyperglycemic events occurred. Pooled results of comparison of mean BG values for day, night and physical activities, - 4.33 [- 6.70, - 1.96] (P = 0.0003), - 16.61 [- 31.68, - 1.54] (P = 0.03) and - 8.27 [- 19.52, 2.99] (P = 0.15). The monitoring for day, night and physical activities for TIR - 13.18 [- 19.18, - 7.17] (P < 0.0001), - 15.36 [- 26.81, - 3.92] (P = 0.009) and - 7.39 [- 17.65, 2.87] (P = 0.16). The day and night results of SD of glucose variability was - 0.40 [- 0.79, - 0.00] (P = 0.05) and - 0.86 [- 2.67, 0.95] (P = 0.35). These values shows the superiority of CLC system in terms of efficacy. The safety evaluation, of the day, night and physical activities observations of average blood glucose goal hypoglycemic events - 0.54 [- 1.86, 0.79] (P = 0.43), 0.04 [- 0.20, 0.27] (P = 0.77) and 0.00 [- 0.25, 0.25] (P = 1.00) and hyperglycemic events - 0.04 [- 0.20, 0.27] (P = 0.77), - 7.11 [- 12.77, - 1.45] (P = 0.01) and - 0.00 [- 0.10, 0.10] (P = 0.97), highlights the commendable safety factor of CLC. The CLC systems can be considered as an ideal preference in the management of adolescents with type 1 diabetes to be used during a 24 h basis.
Indexed as
Identifiers
What Socratic holds
Registered trials