ArticleAnalytical and bioanalytical chemistry2023
Sensitive detection of 17β-estradiol at a picomolar level using an aptamer-assisted liquid crystal-based optical sensor.
Article in Analytical and bioanalytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 6 citations in OpenAlex.
- Recent Progress in Biosensors for Depression Monitoring-Advancing Personalized Treatment.Biosensors · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
A liquid crystal (LC)-based aptasensor was developed that can detect 17β-estradiol (E2) at the picomolar level. This aptasensor is based on competitive reactions of the aptamer that interacts with cetyl trimethyl ammonium bromide (CTAB) and E2 at the aqueous/LC interface. The long alkyl chain of CTAB anchored the 4-cyano-4'-pentylbiphenyl (5CB) to a homeotropic state and controls the local anchoring depending on the extent of electrostatic interaction with the aptamer. Upon addition of the aptamer solution to the CTAB-saturated LC layer, LCs change from dark to bright optical response. This is due to the perturbed orientation of 5CB at the aqueous/LC interface as a result of electrostatic attraction of the cationic group of CTAB and the phosphate group of the aptamer. The conformational change of the aptamer due to specific binding with E2 weakens the electrostatic attraction between CTAB and aptamer. When specific binding becomes relatively dominant, CTAB induces the orientation of LCs to the homeotropic state, resulting in a dark optical image observed. We also analyzed the change in the optical response of LCs according to the interfacial events and compared the grayscale values of the optical image for each concentration of E2 to determine the detection limit. Accordingly, the detection limit of the E2 sensor was found to be 3.1 pM (0.8 pg/ml) in Tris-buffered saline (TBS), and 6.8 pM (1.9 pg/ml) in human urine. The LC-based optical aptasensor was thus shown to be highly sensitive and selective with no requirement for complex analysis equipment.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.