Evidence map›Paper›PMID 37629356›Full record

ArticleJournal of clinical medicine2023

Clinical Outcomes and Prognostic Factors in Complex, High-Risk Indicated Procedure (CHIP) and High-Bleeding-Risk (HBR) Patients Undergoing Percutaneous Coronary Intervention with Sirolimus-Eluting Stent Implantation: 4-Year Results.

Maciej Tyczyński, Adam Kern, Patryk Buller, Wojciech Wańha, Robert J Gil, Jacek Bil

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Application of Drug-Coated Balloons in Complex High Risk and Indicated Percutaneous Coronary Interventions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025
    Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Maciej TyczyńskiDepartment of Invasive Cardiology, Center of Postgraduate Medical Education, 02-508 Warsaw, Poland.
Adam KernDepartment of Cardiology and Internal Medicine, School of Medicine, Collegium Medicum, University of Warmia and Mazury, 10-082 Olsztyn, Poland.ORCID 0000-0003-3341-3701
Patryk BullerDepartment of Cardiology, Provincial Integrated Hospital, 09-400 Plock, Poland.
Wojciech WańhaDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, 40-635 Katowice, Poland.ORCID 0000-0003-1220-9496
Robert J GilDepartment of Cardiology, State Medical Institute of the Ministry of Interior and Administration, 02-508 Warsaw, Poland.
Jacek BilDepartment of Invasive Cardiology, Center of Postgraduate Medical Education, 02-508 Warsaw, Poland.ORCID 0000-0002-8724-5611
Postgraduate School of Molecular Medicine · PLMedical University of Silesia · PLMinistry of Interior and Administration · PLUniversity of Warmia and Mazury in Olsztyn · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We aimed to characterize the performance and safety of percutaneous coronary intervention (PCI) in complex, high-risk indicated procedure (CHIP) and high-bleeding-risk (HBR) patients at a 4-year follow up. We included all consecutive patients who underwent PCI with the sirolimus-eluting coronary stent Alex Plus (Balton, Poland) between July 2015 and March 2016. We analyzed various baseline demographic and clinical characteristics, laboratory data, and clinical outcomes. We enrolled 232 patients in whom 282 stents were implanted, including 81 patients meeting the CHIP criteria and 76 patients meeting the HBR criteria. In the whole population, the mean age was 68 ± 11 years, and 23.7% were females. Most procedures were performed from radial access (83.2%) using a 6F guiding catheter (95.7%). The lesions were mostly predilated (61.6%), and postdilatation was performed in 37.9%. The device success was 99.6% (in one case, a second stent was required due to heavy calcifications). Additional stents were deployed in 39% of cases due to edge dissection (6.9%), side branch stenting (5.2%), or diffuse disease (26.9%). Myocardial infarction (MI) type 4a was revealed in 2.2% of cases. At 4 years, the MACE rates for the whole population and for CHIP and HBR patients were 23.3%, 29.6%, and 27.6%, respectively. CHIP patients had a higher risk of MACEs (29.6% vs. 19.9%, HR 1.69,

Indexed as

Alex Plushigh bleeding riskhigh-risk PCIin-stent restenosismajor cardiovascular adverse eventsSES