Evidence map›Paper›PMID 37649152›Full record

ArticleSmall (Weinheim an der Bergstrasse, Germany)2024

Next-Generation Nanopore Sensors Based on Conductive Pulse Sensing for Enhanced Detection of Nanoparticles.

Samuel Confederat, Seungheon Lee, Der Vang, Dimitrios Soulias, Fabio Marcuccio, Timotheus I Peace, Martin Andrew Edwards, Pietro Strobbia, Devleena Samanta, Christoph Wälti and 1 more

Abstract read
In one paragraph

Article in Small (Weinheim an der Bergstrasse, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Single molecule delivery into living cells.Nature communications · 2024
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Samuel ConfederatBragg Centre for Materials Research, University of Leeds, LS2 9JT, Leeds, UK.
Seungheon LeeDepartment of Chemistry, The University of Texas at Austin, Austin, TX, 78712, USA.ORCID 0000-0001-9631-4853
Der VangDepartment of Chemistry, University of Cincinnati, Cincinnati, OH, 45221, USA.
Dimitrios SouliasBragg Centre for Materials Research, University of Leeds, LS2 9JT, Leeds, UK.
Fabio MarcuccioBragg Centre for Materials Research, University of Leeds, LS2 9JT, Leeds, UK.
Timotheus I PeaceBragg Centre for Materials Research, University of Leeds, LS2 9JT, Leeds, UK.
Martin Andrew EdwardsDepartment of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA.
Pietro StrobbiaDepartment of Chemistry, University of Cincinnati, Cincinnati, OH, 45221, USA.
Devleena SamantaDepartment of Chemistry, The University of Texas at Austin, Austin, TX, 78712, USA.ORCID 0000-0002-0647-7673
Christoph WältiBragg Centre for Materials Research, University of Leeds, LS2 9JT, Leeds, UK.
Paolo ActisBragg Centre for Materials Research, University of Leeds, LS2 9JT, Leeds, UK.ORCID 0000-0002-7146-1854

Funding

European Research Council 788968Medical Research Council MR/N029976/1
6 · The paper itself

Abstract

Nanopore sensing has been successfully used to characterize biological molecules with single-molecule resolution based on the resistive pulse sensing approach. However, its use in nanoparticle characterization has been constrained by the need to tailor the nanopore aperture size to the size of the analyte, precluding the analysis of heterogeneous samples. Additionally, nanopore sensors often require the use of high salt concentrations to improve the signal-to-noise ratio, which further limits their ability to study a wide range of nanoparticles that are unstable at high ionic strength. Here, a new paradigm in nanopore research that takes advantage of a polymer electrolyte system to comprise a conductive pulse sensing approach is presented. A finite element model is developed to explain the conductive pulse signals observed and compare these results with experiments. This system enables the analytical characterization of heterogeneous nanoparticle mixtures at low ionic strength . Furthermore, the wide applicability of the method is demonstrated by characterizing metallic nanospheres of varied sizes, plasmonic nanostars with various degrees of branching, and protein-based spherical nucleic acids with different oligonucleotide loadings. This system will complement the toolbox of nanomaterials characterization techniques to enable real-time optimization workflow for engineering a wide range of nanomaterials.

Indexed as

NanoparticlesNanoporesNucleic AcidsNanotechnologyProteinsNucleic AcidsProteinsfunctionalized proteinsnanoparticle characterizationnanoparticle mixturesnanoporessingle-molecule analysis

Identifiers

PMID37649152
PMCPMC11475450

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.