ArticleDiagnostics (Basel, Switzerland)2023
Evaluating the Efficiency of the Cobas 6800 System for BK Virus Detection in Plasma and Urine Samples.
Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- The impact of FDA-cleared molecular solutions for BK polyomavirus quantitation.Journal of clinical microbiology · 2025Review
- Performance evaluation of the high-throughput quantitative Alinity m BK virus assay.Journal of clinical microbiology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We evaluated the overall performance of the Cobas 6800 BKV test in detecting BK virus (BKV). We examined the imprecision of the Cobas 6800 BKV test and compared the qualitative and quantitative results obtained from the Cobas 6800 BKV test and the Real-Q BKV quantification assay. We assessed 88 plasma and 26 urine samples collected between September and November 2022 from patients with BKV infection using the Real-Q BKV quantitative assay. The lognormal coefficient of variation indicated that the inter-assay precision of the Cobas 6800 BKV test ranged from 13.86 to 33.83%. A strong correlation was observed between the quantitative results obtained using the Cobas 6800 BKV test and the Real-Q BKV quantification assay for plasma samples. The Spearman's rank correlation coefficients (ρ) for plasma, polymerase chain reaction (PCR) media-stabilized urine, and raw urine samples were 0.939, 0.874, and 0.888, respectively. Our analyses suggest that the Cobas 6800 BKV test is suitable for clinical applications owing to the strong correlation between the results obtained using this test and the Real-Q BKV quantification assay in plasma and urine samples. Furthermore, utilizing fresh raw urine samples can be a viable approach for the Cobas 6800 BKV test as it is less labor- and time-intensive.
Indexed as
Identifiers
What Socratic holds
Registered trials