Evidence map›Paper›PMID 37697803›Full record

ArticleTherapeutic advances in cardiovascular disease

Assessment of atrial septal defects using 3-dimensional transthoracic echocardiography prior to percutaneous device closure: first report from Bangladesh.

Santosh Kumar Saha, Chaudhury Meshkat Ahmed, Tuhin Haque, Mohammad Abdullah Al Mamun, Mohd Zahid Hussain

Open access · goldAbstract read
In one paragraph

Article in Therapeutic advances in cardiovascular disease. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Santosh Kumar SahaDepartment of Pediatric Cardiology, National Institute of Cardiovascular Diseases and Hospital, Sher-e- Bangla Nagar, Dhaka 1207, Bangladesh.ORCID 0000-0002-5402-3414
Chaudhury Meshkat AhmedDepartment of Cardiology, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh.
Tuhin HaqueDepartment of Cardiology, National Heart Foundation Hospital and Research Institute, Dhaka, Bangladesh.
Mohammad Abdullah Al MamunDepartment of Epidemiology and Research, National Heart Foundation Hospital and Research Institute, Dhaka, Bangladesh.
Mohd Zahid HussainDepartment of Pediatric Cardiology, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh.
Bangladesh Medical University · BDNational Heart Foundation Hospital & Research Institute · BDNational Institute of Cardiovascular Diseases · BD

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSecundum atrial septal defect (ASD) is treated following trans-catheter closure in alternative to surgical treatment. Per-intervention selection of device size with balloon occlusive diameter (BOD) often cause tearing or enlarging, causing arrhythmias and hypotension. We assessed the suitability of percutaneous device closure for ASD using 3-dimensional transthoracic echocardiography (3DTTE).

objectivesThis study was conducted to investigate if 3DTTE could be an alternative of balloon sizing for selection of device size in atrial septal defect device closure.

designIt was a cross-sectional comparative study.

methodsThis study was conducted at the department of Pediatric Cardiology, Bangabandhu Sheikh Mujib Medical University for a period of 2 years. Thirty-three purposively selected secundum ASD patients suitable for device closure were included in the study. Ethical permission was taken from the Institutional Review Board and written consent was taken from each patient's guardian. In this study, 3DTTE derived ASD diameter and BOD were compared with that of deployed device size using correlation analysis.

resultsOut of 33 patients, 63.6% were female and 36.4% were males had a mean age of 18.07 ± 14.58 years (range 2-55 years). Mean diameter of ASD measured by 2-dimensional (2D) and 3-dimensional (3D) echocardiography were 17.09 ± 6.08 mm and 21.30 ± 6.56 mm, respectively, yielding a significant difference (

conclusion3DTTE can accurately measure ASD diameter and can be used as an alternate, effective, and safe method to select device size.

Indexed as

Echocardiography, Three-DimensionalHeart Septal Defects, AtrialSeptal Occluder DeviceAdolescentAdultBangladeshCardiac CatheterizationChildChild, PreschoolCross-Sectional StudiesEchocardiographyEchocardiography, TransesophagealFemaleHumansMaleMiddle Aged3-dimensional transthoracic echocardiographyatrial septal defectballoon occlusive diameterBangladeshdevice closure

Identifiers

PMID37697803
PMCPMC10496463
OpenAlexW4386624599

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.