Evidence map›Paper›PMID 37702889›Full record

ArticleEJNMMI physics2023

Gamma camera-specific reference standards for radioactive iodine uptake measurements.

Jurgen E M Mourik, Mark Derks, Erik T Te Beek, Marc R J Ten Broek

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Jurgen E M MourikDepartment of Nuclear Medicine, Franciscus Gasthuis & Vlietland Hospital, Kleiweg 500, 3045 PM, Rotterdam, The Netherlands. J.Mourik@franciscus.nl.ORCID http://orcid.org/0000-0002-8108-6955
Mark DerksDepartment of Nuclear Medicine, IJsselland Hospital, Capelle aan den IJssel, The Netherlands.
Erik T Te BeekDepartment of Nuclear Medicine, Reinier de Graaf Hospital, Delft, The Netherlands.
Marc R J Ten BroekDepartment of Nuclear Medicine, IJsselland Hospital, Capelle aan den IJssel, The Netherlands.
Reinier de Graaf Hospital · NLIJsselland Ziekenhuis · NLSint Franciscus Gasthuis · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCurrent guidelines of the radioiodine uptake (RAIU) test allow the use of different equipment, isotopes, activity and region-of-interest (ROI). We evaluated presence and extent of these differences in clinical practice and evaluated the effect of some of these variations on RAIU outcomes. Also, gamma camera-specific reference standards were calculated and retrospectively compared with measurements obtained during clinical RAIU tests. MATERIALS AND

methodsFirst, questionnaires were sent to Dutch nuclear medicine departments requesting information about equipment usage, isotope, isotope formulation, activity and measurement techniques. Secondly, a neck phantom containing a range of activities in capsule or water-dissolved formulation was scanned. Counts were measured using automatic ROI, square box ROI or all counts in the image. Thirdly, clinical RAIU data were collected during 2015-2018 using three different gamma cameras. Reference standards for each scanner were calculated using regression analysis between reference activity and measured counts. Uptake measurements using this gamma camera-specific reference standard were compared with original measurements.

resultsThe survey demonstrated significant differences in isotope, isotope formulation, activity, use of neck phantoms, frequency and duration of reference measurements, distance to collimator, use of background measurements and ROI delineation. The phantom study demonstrated higher counts for the water-dissolved formulation than capsules using both automatic and square box ROI. Also, higher counts were found using a square box ROI than an automatic ROI. The retrospective study showed feasibility of RAIU calculations using camera-specific reference standards and good correlation with the original RAIU measurements.

conclusionsThis study demonstrated considerable technical variation in RAIU measurement in clinical practice. The phantom study demonstrated that these differences could result in differences in count measurements, potentially resulting in different dose calculations for radioactive iodine therapy. Retrospective data suggest that camera-specific reference standards may be used instead of individual reference measurements using separate activity sources, which may thus eliminate some sources of variation.

Indexed as

Gamma cameraIsotope formulationRadioiodine uptake testRAIUReference standardRegion-of-interest

Identifiers

PMID37702889
PMCPMC10499732
OpenAlexW4386695860

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.