ArticleProceedings of the National Academy of Sciences of the United States of America2023
Physical mechanisms of red blood cell splenic filtration.
Article in Proceedings of the National Academy of Sciences of the United States of America, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 23 citations in OpenAlex.
- Erythrocyte invasion in malaria: from molecular mechanisms to rational vaccines.Nature reviews. Microbiology · 2026Review
- Choice of lipid supplementation for in vitro erythroid cell culture impacts reticulocyte yield and characteristics.Scientific reports · 2026Article
- Variable surface antigen expression, virulence, and persistent infection byMicrobiology and molecular biology reviews : MMBR · 2025Review
- Mechanical Stimulation of Red Blood Cells Aging: Focusing on the Microfluidics Application.Micromachines · 2025Review
- PIEZO channels as multimodal mechanotransducers.Biochemical Society transactions · 2025Review
- Reply to Kaestner et al.: Activation of PIEZO1 is not significant for the passage of red blood cells through biomimetic splenic slits.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Splenic filtration of red blood cells: Physics, chemistry, and biology need to go hand in hand.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- An overview of hereditary spherocytosis and the curative effects of splenectomy.Frontiers in physiology · 2025Review
- Red blood cell passage through deformable interendothelial slits in the spleen: Insights into splenic filtration and hemodynamics.Computers in biology and medicine · 2024Article
- Erythroblast enucleation at a glance.Journal of cell science · 2024Review
- Deformability of Heterogeneous Red Blood Cells in Aging and Related Pathologies.Aging and disease · 2024Review
- Transit Time Theory for a Droplet Passing through a Slit in Pressure-Driven Low Reynolds Number Flows.Micromachines · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
Abstract
The splenic interendothelial slits fulfill the essential function of continuously filtering red blood cells (RBCs) from the bloodstream to eliminate abnormal and aged cells. To date, the process by which 8 [Formula: see text]m RBCs pass through 0.3 [Formula: see text]m-wide slits remains enigmatic. Does the slit caliber increase during RBC passage as sometimes suggested? Here, we elucidated the mechanisms that govern the RBC retention or passage dynamics in slits by combining multiscale modeling, live imaging, and microfluidic experiments on an original device with submicron-wide physiologically calibrated slits. We observed that healthy RBCs pass through 0.28 [Formula: see text]m-wide rigid slits at 37 °C. To achieve this feat, they must meet two requirements. Geometrically, their surface area-to-volume ratio must be compatible with a shape in two tether-connected equal spheres. Mechanically, the cells with a low surface area-to-volume ratio (28% of RBCs in a 0.4 [Formula: see text]m-wide slit) must locally unfold their spectrin cytoskeleton inside the slit. In contrast, activation of the mechanosensitive PIEZO1 channel is not required. The RBC transit time through the slits follows a [Formula: see text]1 and [Formula: see text]3 power law with in-slit pressure drop and slip width, respectively. This law is similar to that of a Newtonian fluid in a two-dimensional Poiseuille flow, showing that the dynamics of RBCs is controlled by their cytoplasmic viscosity. Altogether, our results show that filtration through submicron-wide slits is possible without further slit opening. Furthermore, our approach addresses the critical need for in vitro evaluation of splenic clearance of diseased or engineered RBCs for transfusion and drug delivery.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.