Evidence map›Paper›PMID 37883443›Full record

SynthesisPloS one2023

A systematic review of passing fit testing of the masks and respirators used during the COVID-19 pandemic: Part 1-quantitative fit test procedures.

Anahita Fakherpour, Mehdi Jahangiri, Janis Jansz

Open access · goldAbstract readSystematic Review
In one paragraph

Synthesis in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
1.8field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Anahita FakherpourStudent Research Committee, Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
Mehdi JahangiriDepartment of Occupational Health and Safety Engineering, Research Center for Health Sciences, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
Janis JanszSchool of Mines: Minerals, Energy and Chemical Engineering, Faculty of Science and Engineering, Curtin University, Perth, Australia.
Shiraz University of Medical Sciences · IRCurtin University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring respiratory infection pandemics, masks and respirators are highly sought after, especially for frontline healthcare workers and patients carrying respiratory viruses. The objective of this study was to systematically review fit test pass rates and identify factors influencing the fitting characteristics.

methodsPotentially relevant studies were identified using PubMed, Scopus, Web of Science, and Science Direct during the COVID-19 pandemic from February 5, 2020, to March 21, 2023. The search strategy using the following keywords was conducted: Quantitative Fit Test, Condensation Nuclei Counter, Controlled Negative Pressure, PortaCount, Sibata, Accufit, Fit, Seal, Mask, Respirator, Respiratory Protective Device, Respiratory Protective Equipment, Protective Device, Personal Protective Equipment, COVID-19, Coronavirus, and SARS-CoV-2. The quality of the included studies was also assessed using the Newcastle-Ottawa scale.

resultsA total of 137 articles met the eligibility criteria. Fifty articles had a quality score of less than 7 (good quality). A total of 21 studies had a fit test pass rate of less than 50%. 26 studies on disposable respirators and 11 studies on reusable respirators had an FF of less than 50 and less than 200, respectively. The most influential factors include respirator brand/model, style, gender, ethnicity, facial dimensions, facial hair, age, reuse, extensive movement, seal check, comfort and usability assessment, and training.

conclusion37.36% of the disposable respirator studies and 43% of the reusable respirator studies did not report fit test results. 67.86% of the disposable respirator studies had a fit test pass rate greater than 50%, and 35.84% of these studies had an FF greater than 100. Also, 85.71% of the reusable respirator studies had a fit test pass rate greater than 50%, and 52.77% of these studies had an FF greater than 1000. Overall, the fit test pass rate was relatively acceptable. Newly developed or modified respirators must undergo reliable testing to ensure the protection of HCWs. Subject and respirator characteristics should be considered when implementing fit testing protocols. An optimal fit test panel should be developed prior to respirator design, certification, procurement decisions, and selection procedures.

Indexed as

COVID-19Occupational ExposureRespiratory Protective DevicesEquipment DesignHumansPandemicsSARS-CoV-2User-Computer InterfaceVentilators, Mechanical

Identifiers

PMID37883443
PMCPMC10602271
OpenAlexW4387952617

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.