Evidence map›Paper›PMID 37893405›Full record

ArticleMicromachines2023

Design and Application of Portable Centrifuge Inspired by a Hand-Powered Spinning Top.

Dongbao Tang, Ziwei Duan, Luxuan Liu, Zhaoyuan Jia, Lijun Lang, Yuyu Tan

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 58% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Dongbao TangSchool of Electrical Engineering, Ultra-Fast/Micro-Nano Technology and Advanced Laser Manufacturing Key Laboratory of Hunan Province, University of South China, Hengyang 421001, China.
Ziwei DuanSchool of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China.
Luxuan LiuSchool of Electrical Engineering, Ultra-Fast/Micro-Nano Technology and Advanced Laser Manufacturing Key Laboratory of Hunan Province, University of South China, Hengyang 421001, China.
Zhaoyuan JiaSchool of Electrical Engineering, Ultra-Fast/Micro-Nano Technology and Advanced Laser Manufacturing Key Laboratory of Hunan Province, University of South China, Hengyang 421001, China.
Lijun LangDepartment of Computer Science and Engineering, Ho Sin-Hang Engineering Building, Chinese University of Hong Kong, Hong Kong 999077, Hong Kong SAR, China.ORCID 0000-0001-6076-2187
Yuyu TanSchool of Electrical Engineering, Ultra-Fast/Micro-Nano Technology and Advanced Laser Manufacturing Key Laboratory of Hunan Province, University of South China, Hengyang 421001, China.
University of South China · CNChinese University of Hong Kong · HKSun Yat-sen University · CN

Funding

Hunan Province Key Laboratory for Ultra-Fast Micro/Nano Technology and Advanced Laser Manufacture 2018TP1041The Natural Science Foundation of Hunan Province 2020JJ4533The Ph.D. Start-up Foundation of University of South China 190XQD046The Research Foundation of Education Bureau of Hunan Province 21B0427
6 · The paper itself

Abstract

Traditional centrifuges, extensively employed in biology, chemistry, medicine, and other domains for tasks such as blood separation and pathogen extraction, have certain limitations. Their high cost, substantial size, and reliance on electricity restrict their range of application. Contemporary centrifuges, inspired by everyday items like paper trays and egg beaters, boast characteristics such as ease of operation, independence from electricity, and portability. These features offer unique advantages in specific situations, such as electricity shortages, inadequate infrastructure, and challenging medical conditions. Consequently, we designed a hand-powered portable centrifuge driven by pulling a rope. Our experiments revealed significant performance factors, including load capacity, rope length, and frequency of rope pulling. The results demonstrated that the revolutions per minute (RPM) of a hand-powered portable centrifuge were directly proportional to the length of the rope and the frequency of pulling, up to a certain limit, while inversely proportional to the load. When used for separating and washing polystyrene microspheres, the portable centrifuge's performance equaled that of traditional centrifuges. According to relevant calculations, this centrifuge could be capable of meeting the application of blood separation. Therefore, we believe this portable centrifuge will find meaningful applications in similar areas, particularly in resource-poor settings.

Indexed as

electricity-freehand-poweredportable centrifugetop-inspired

Identifiers

PMID37893405
PMCPMC10609382
OpenAlexW4387878028

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.