Evidence map›Paper›PMID 37899254›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2025

Low b-value Diffusion Tensor Imaging to Analyze the Dynamics of Cerebrospinal Fluid: Resolving Intravoxel Pseudorandom Motion into Ordered and Disordered Motions.

Yoshitaka Bito, Hisaaki Ochi, Ryuji Shirase, Wataru Yokohama, Kuniaki Harada, Kohsuke Kudo

Abstract read
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Diffusion Tensor Imaging in Neurofluids.Neuroimaging clinics of North America · 2025
    Review
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yoshitaka BitoFUJIFILM Healthcare Corporation.
Hisaaki OchiFUJIFILM Healthcare Corporation.
Ryuji ShiraseFUJIFILM Healthcare Corporation.
Wataru YokohamaFUJIFILM Healthcare Corporation.
Kuniaki HaradaDepartment of Diagnostic Imaging, Hokkaido University Graduate School of Medicine.
Kohsuke KudoDepartment of Diagnostic Imaging, Hokkaido University Graduate School of Medicine.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAnalysis of cerebrospinal fluid (CSF) dynamics may be beneficial for understanding the mechanisms and diagnosis of several neurological diseases. Low b-value diffusion tensor imaging (low-b DTI) is useful for observing the slow and complex motion of the CSF. Theoretically, a mathematical framework suggests that low-b DTI provides the variance of the pseudorandom motion of the CSF. Furthermore, low-b DTI could provide comprehensive information on fluid dynamics. Accordingly, we proposed an analysis technique that resolves intravoxel pseudorandom motion into ordered (linear) and disordered (random) motions based on the mathematical framework.

methodsThe proposed analysis technique helps measure low-b DTI with multiple diffusion times and linearly fits its mean diffusivity (MD) with the diffusion time to obtain two parameters, double-slope V

resultsThe obtained data showed the validity of the technique, repeatability, and consistency across the subjects in ROIs, such as the lateral ventricle (LV), third ventricle (3V), fourth ventricle (4V), and Sylvian fissure (SF). The obtained parameters V

conclusionThe proposed analysis technique will facilitate a comprehensive investigation of the complex dynamics of the CSF using resolved parameters representing ordered and disordered motions.

Indexed as

Cerebrospinal FluidDiffusion Tensor ImagingMotionAdultAlgorithmsBrainFemaleHumansImage Processing, Computer-AssistedMaleReproducibility of ResultsYoung Adultcerebrospinal fluiddiffusiondynamicsflowneurofluid

Identifiers

PMID37899254
PMCPMC11733514

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.