Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use.

Sissel Banner Lundemose, Christian Laugesen, Ajenthen Gayathri Ranjan, Kirsten Nørgaard

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Observational
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sissel Banner LundemoseSteno Diabetes Center Copenhagen, Clinical Research, Diabetes Technology Research, Borgmester Ib Juuls Vej 83, DK-2730 Herlev, Denmark.ORCID 0000-0002-4343-7777
Christian LaugesenSteno Diabetes Center Copenhagen, Clinical Research, Diabetes Technology Research, Borgmester Ib Juuls Vej 83, DK-2730 Herlev, Denmark.ORCID 0000-0001-9253-9457
Ajenthen Gayathri RanjanSteno Diabetes Center Copenhagen, Clinical Research, Diabetes Technology Research, Borgmester Ib Juuls Vej 83, DK-2730 Herlev, Denmark.
Kirsten NørgaardSteno Diabetes Center Copenhagen, Clinical Research, Diabetes Technology Research, Borgmester Ib Juuls Vej 83, DK-2730 Herlev, Denmark.ORCID 0000-0003-1620-8271

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous glucose monitors (CGMs) are valuable tools for improving glycemic control, yet their accuracy might be influenced by physical activity. This study sought to assess the accuracy of the three latest factory-calibrated CGM systems available in Europe at the time the study was conducted, both during aerobic exercise and in typical daily scenarios. The accuracy evaluation, based on metrics such as the median absolute relative difference (MARD) and point and rate error-grid analyses (PEGA and REGA), involved 13 adults with type 1 diabetes. Participants wore all sensors during a 1 h in-clinic exercise session followed by a subsequent 3-day home period, with blood glucose measurements serving as reference values in both contexts. During exercise, no statistically significant differences in MARD were observed (Dexcom G6: 12.6%, Guardian 4: 10.7%, and Freestyle Libre 2: 17.2%;

Indexed as

Diabetes Mellitus, Type 1AdultBlood GlucoseBlood Glucose Self-MonitoringCalibrationExerciseHumansReproducibility of ResultsBlood Glucoseaccuracycontinuous glucose monitoringexercisetype 1 diabetes

Identifiers

PMID38005642
PMCPMC10675113

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.