Evidence map›Paper›PMID 38141036›Full record

ArticleACS sensors2024

Ultrasensitive ImmunoMag-CRISPR Lateral Flow Assay for Point-of-Care Testing of Urinary Biomarkers.

Inseon Lee, Seok-Joon Kwon, Peter Heeger, Jonathan S Dordick

Open access · greenAbstract read
In one paragraph

Article in ACS sensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 31 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Inseon LeeDepartment of Chemical and Biological Engineering, and Center for Biotechnology & Interdisciplinary Studies, Rensselaer Polytechnic Institute, 110 Eighth Street, Troy, New York 12180, United States.
Seok-Joon KwonDepartment of Chemical and Biological Engineering, and Center for Biotechnology & Interdisciplinary Studies, Rensselaer Polytechnic Institute, 110 Eighth Street, Troy, New York 12180, United States.
Peter HeegerComprehensive Transplant Center, Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California 90048, United States.
Jonathan S DordickDepartment of Chemical and Biological Engineering, and Center for Biotechnology & Interdisciplinary Studies, Rensselaer Polytechnic Institute, 110 Eighth Street, Troy, New York 12180, United States.ORCID 0000-0001-7802-3702
Rensselaer Polytechnic Institute · USCedars-Sinai Medical Center · US

Funding

Noninvasive Markers and Transplant Outcome in HumansU01AI063594 · NIAID · ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI · PI HEEGER, PETER SCOTT · 2004 to 2022
$66.5M
Assessment of Biomarker Guided CNI Substitution in Kidney TransplantationU01AI170424 · NIAID · CEDARS-SINAI MEDICAL CENTER · PI Peter Scott Heeger, PETER W NICKERSON · 2022 to 2026
$21.3M
NIAID NIH HHS U01 AI063594NIAID NIH HHS U01 AI170424
6 · The paper itself

Abstract

Rapid, accurate, and noninvasive detection of biomarkers in saliva, urine, or nasal fluid is essential for the identification, early diagnosis, and monitoring of cancer, organ failure, transplant rejection, vascular diseases, autoimmune disorders, and infectious diseases. We report the development of an Immuno-CRISPR-based lateral flow assay (LFA) using antibody-DNA barcode complexes with magnetic enrichment of the target urinary biomarkers CXCL9 and CXCL10 for naked eye detection (ImmunoMag-CRISPR LFA). An intermediate approach involving a magnetic bead-based Immuno-CRISPR assay (ImmunoMag-CRISPR) resulted in a limit of detection (LOD) of 0.6 pg/mL for CXCL9. This value surpasses the detection limits achieved by previously reported assays. The highly sensitive detection method was then re-engineered into an LFA format with an LOD of 18 pg/mL for CXCL9, thereby enabling noninvasive early detection of acute kidney transplant rejection. The ImmunoMag-CRISPR LFA was tested on 42 clinical urine samples from kidney transplant recipients, and the assay could determine 11 positive and 31 negative urinary samples through a simple visual comparison of the test line and the control line of the LFA strip. The LFA system was then expanded to quantify the CXCL9 and CXCL10 levels in clinical urine samples from images. This approach has the potential to be extended to a wide range of point-of-care tests for highly sensitive biomarker detection.

Indexed as

Point-of-Care TestingBiomarkersBiomarkersCRISPR-Cas12aELISAkidney transplant rejectionlateral flow assayurinary CXCL9 and CXCL10

Identifiers

PMID38141036
PMCPMC11090086
OpenAlexW4390142192

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.