Evidence map›Paper›PMID 38189290›Full record

ArticleJournal of diabetes science and technology2024

Comparison of Point Accuracy Between Two Widely Used Continuous Glucose Monitoring Systems.

Kevin Hanson, Mark Kipnes, Hien Tran

Abstract readComparative StudyMulticenter Study
In one paragraph

Article in Journal of diabetes science and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Accuracy and Reliability of the Sinocare Continuous Glucose Monitoring System.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2025
    Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kevin HansonEastside Research Associates, Redmond, WA, USA.
Mark KipnesDiabetes & Glandular Disease Clinic, San Antonio, TX, USA.
Hien TranTexas Diabetes and Endocrinology, Round Rock, TX, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSafe and effective self-management of glucose levels requires immediate access to accurate data. We assessed the point accuracy of the Dexcom G7 Continuous Glucose Monitoring System (Dexcom, Inc., San Diego, CA, USA) and FreeStyle Libre 3 (Abbott Diabetes Care, Alameda, CA, USA) sensors in a head-to-head comparison.

methodMulticenter, single-arm, prospective, nonsignificant risk evaluation enrolled adults (≥ 18 years) with diagnosed type 1 diabetes (T1D) or type 2 diabetes (T2D). Accuracy was assessed by comparing sensor data to laboratory reference values Yellow Springs Instrument [YSI] and capillary blood glucose values. Outcome measures were differences in mean absolute relative difference (MARD), number and percentage of matched glucose pairs within ±20 mg/dL/±20 of reference values within glucose ranges: < 54, 54 to 69, 70 to 180, 181 to 250, > 250 mg/dL, and combined.

resultsData from 55 adults were included in the analysis. Analysis showed significantly lower MARD with the FreeStyle Libre 3 sensor vs the Dexcom G7 sensor (8.9% vs 13.6%, respectively,

conclusionsThe FreeStyle Libre 3 sensor was more accurate than the Dexcom G7 sensor in all metrics evaluated throughout the study period. This is the first head-to-head study to our knowledge that compares the flagship products currently in widespread use of the two largest CGM manufacturers.

Indexed as

Continuous Glucose MonitoringDiabetes Mellitus, Type 1Diabetes Mellitus, Type 2AdultAgedBlood GlucoseFemaleHumansMaleMiddle AgedProspective StudiesReproducibility of ResultsBlood Glucoseaccuracyblood glucose meterCGMMARD

Identifiers

PMID38189290
PMCPMC11089878

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.