Evidence map›Paper›PMID 38313007›Full record

ArticlePeerJ2024

Neck circumference is a highly reliable anthropometric measure in older adults requiring long-term care.

Ryo Sato, Yohei Sawaya, Masahiro Ishizaka, Lu Yin, Takahiro Shiba, Tamaki Hirose, Tomohiko Urano

Open access · goldAbstract read
In one paragraph

Article in PeerJ, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Ryo Sato *Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
Yohei Sawaya *Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.ORCID 0000-0001-5679-2391
Masahiro IshizakaDepartment of Physical Therapy, School of Health Sciences, International University of Health and Welfare, Otawara, Tochigi, Japan.ORCID 0000-0001-6115-1900
Lu YinDepartment of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
Takahiro ShibaDepartment of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
Tamaki HiroseDepartment of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
Tomohiko UranoDepartment of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.ORCID 0000-0002-1771-024X
International University of Health and Welfare · JPFuruno (Japan) · JP

Funding

Japan Society for the Promotion of Science Grants-in-Aid for Scientific Research
6 · The paper itself

Abstract

The reliability of neck circumference measurement as an assessment tool for older adults requiring long-term care remains unknown. This study aimed to evaluate the reliability of neck circumference measurement in older adults requiring long-term care, and the effect of edema on measurement error. Two physical therapists measured the neck circumference. Intraclass correlation coefficient (ICC) and Bland-Altman analyses were performed to examine the reliability of neck circumference measurement. Correlation analysis was used to evaluate the relationship between edema values (extracellular water/total body water) and neck circumference measurement difference. For inter-rater reliability of neck circumference measurement, the overall ICC (2,1) was 0.98. The upper and lower limits of the difference between examiners ranged from -0.9 to 1.2 cm. There was no association between edema values and neck circumference measurement error. Thus, measurement of the neck circumference in older adults requiring long-term care is a reliable assessment tool, with a low error rate, even in older adults with edema.

Indexed as

Long-Term CareNeckAgedEdemaHumansObserver VariationReproducibility of ResultsBioelectric impedance analysisEdemaLong-term careNeck circumferenceReliability

Identifiers

PMID38313007
PMCPMC10838066
OpenAlexW4391389672

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.