Evidence map›Paper›PMID 38383141›Full record

ArticleEuropean journal of hospital pharmacy : science and practice2025

Effect of a smart temperature logger on correctly storing biological disease-modifying antirheumatic drugs at home: a pre-post study.

Lex L Haegens, Victor J B Huiskes, Charlotte L Bekker, Bart J F van den Bemt

Abstract read
In one paragraph

Article in European journal of hospital pharmacy : science and practice, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lex L HaegensDepartment of Research, Sint Maartenskliniek, Nijmegen, The Netherlands l.haegens@maartenskliniek.nl.ORCID http://orcid.org/0000-0003-1850-4365
Victor J B HuiskesDepartment of Pharmacy, Sint Maartenskliniek, Nijmegen, Gelderland, The Netherlands.
Charlotte L BekkerDepartment of Pharmacy, Radboudumc, Nijmegen, Gelderland, The Netherlands.
Bart J F van den BemtDepartment of Pharmacy, Sint Maartenskliniek, Nijmegen, Gelderland, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesBiological disease-modifying antirheumatic drugs (bDMARDs) require specific storage temperatures, but are frequently stored outside the recommended range of 2-8°C. As incorrect storage may affect therapy effectiveness and consequently lead to higher disease activity, compliance with recommended storage temperatures should be improved. eHealth interventions can provide insight into storage temperatures and alerts in case of deviations from recommended temperatures. Therefore, this study aims to assess the effect of a smart temperature logger on correctly storing bDMARDs at home by patients with rheumatic diseases.

methodsA pre-post study was performed in a hospital in the Netherlands. The baseline period consisted of 12 weeks of storage temperature measurement with a passive temperature logger, and the intervention period consisted of 12 weeks of storage temperature measurement with a smart temperature logger. This smart logger included a smartphone application which provided insight into storage temperatures and real-time alerts when exceeding recommended temperatures. The main outcome measure was the difference in the number of patients who stored their bDMARDs correctly between baseline and intervention. Secondary outcomes were the difference in the proportion of measurement time within 2-8°C between baseline and intervention, the distribution of measurement time among temperature categories, and the patient's acceptance measured using a questionnaire based on the Technology Acceptance Model.

resultsIn total, 48 participants (median age 55 years (IQR 47-64), 53% male) were analysed. The proportion of participants correctly storing bDMARDs increased from 18.8% (n=9) during baseline to 39.6% (n=19) during intervention (p=0.004). The median proportion of measurement time between 2-8°C improved by 6% (IQR 0-34%) (p<0.0001). Technology acceptance was scored as moderate.

conclusionsTemperature monitoring and real-time feedback with a smart temperature logger shows potential to improve at-home storage of bDMARDs, provided that continuous connection is realised to ensure real-time alerts and data collection.

Indexed as

Antirheumatic AgentsDrug StorageMobile ApplicationsTemperatureAdultAgedFemaleHumansMaleMiddle AgedNetherlandsRheumatic DiseasesSmartphoneAntirheumatic AgentsDRUG-RELATED SIDE EFFECTS AND ADVERSE REACTIONSPHARMACY SERVICE, HOSPITALPREVENTIVE MEDICINERheumatology

Identifiers

PMID38383141
PMCPMC12573379

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.