Evidence map›Paper›PMID 38398937›Full record

ArticleMicromachines2024

A High-Resolution 3D Ultrasound Imaging System Oriented towards a Specific Application in Breast Cancer Detection Based on a 1 × 256 Ring Array.

Junhui Zhang, Fei Wu, Fansheng Meng, Guojun Zhang, Renxin Wang, Yuhua Yang, Jiangong Cui, Changde He, Licheng Jia, Wendong Zhang

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Junhui ZhangState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Fei WuState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Fansheng MengState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Guojun ZhangState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Renxin WangState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Yuhua YangState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Jiangong CuiState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.ORCID 0000-0001-6572-2045
Changde HeState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.
Licheng JiaState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.ORCID 0000-0003-0968-6953
Wendong ZhangState Key Laboratory of Instrumentation Science and Dynamic Measurement Technology, North University of China, Taiyuan 030051, China.ORCID 0000-0003-1762-9246

Funding

China Postdoctoral Science Foundation 2023M733277Key research and development program by the Ministry of Science and Technology 2022YFB3204302National Natural Science Foundation of China 61927807National Natural Science Foundation of China 62304208Shanxi Province Science Foundation for Youths 202203021222025
6 · The paper itself

Abstract

This paper presents the design and development of a high-resolution 3D ultrasound imaging system based on a 1 × 256 piezoelectric ring array, achieving an accuracy of 0.1 mm in both ascending and descending modes. The system achieves an imaging spatial resolution of approximately 0.78 mm. A 256 × 32 cylindrical sensor array and a digital phantom of breast tissue were constructed using the k-Wave toolbox. The signal is acquired layer by layer using 3D acoustic time-domain simulation, resulting in the collection of data from each of the 32 layers. The 1 × 256 ring array moves on a vertical trajectory from the chest wall to the nipple at a constant speed. A data set was collected at intervals of 1.5 mm, resulting in a total of 32 data sets. Surface rendering and volume rendering algorithms were used to reconstruct 3D ultrasound images from the volume data obtained via simulation so that the smallest simulated reconstructed lesion had a diameter of 0.3 mm. The reconstructed three-dimensional image derived from the experimental data exhibits the contour of the breast model along with its internal mass. Reconstructable dimensions can be achieved up to approximately 0.78 mm. The feasibility of applying the system to 3D breast ultrasound imaging has been demonstrated, demonstrating its attributes of resolution, precision, and exceptional efficiency.

Indexed as

3D ultrasound imaging systembreast imaginghigh-resolutionring arrayultrasonic tomography

Identifiers

PMID38398937
PMCPMC10891686

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.