ArticleBiomedical optics express2024
Self-supervised Self2Self denoising strategy for OCT speckle reduction with a single noisy image.
Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Physics-informed self-supervised denoising for fluorescence microscopy via structure and intensity priors.iScience · 2026Article
- Interferometric image denoising network SEVReNet.Biomedical optics express · 2026Article
- Deep learning-enabled speckle reduction for cleared-sample coherent scattering tomography.bioRxiv : the preprint server for biology · 2026Article
- Probabilistic volumetric speckle suppression in OCT using deep learning.Biomedical optics express · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Optical coherence tomography (OCT) inevitably suffers from the influence of speckles originating from multiple scattered photons owing to its low-coherence interferometry property. Although various deep learning schemes have been proposed for OCT despeckling, they typically suffer from the requirement for ground-truth images, which are difficult to collect in clinical practice. To alleviate the influences of speckles without requiring ground-truth images, this paper presents a self-supervised deep learning scheme, namely, Self2Self strategy (S2Snet), for OCT despeckling using a single noisy image. Specifically, in this study, the main deep learning architecture is the Self2Self network, with its partial convolution being updated with a gated convolution layer. Specifically, both the input images and their Bernoulli sampling instances are adopted as network input first, and then, a devised loss function is integrated into the network to remove the background noise. Finally, the denoised output is estimated using the average of multiple predicted outputs. Experiments with various OCT datasets are conducted to verify the effectiveness of the proposed S2Snet scheme. Results compared with those of the existing methods demonstrate that S2Snet not only outperforms those existing self-supervised deep learning methods but also achieves better performances than those non-deep learning ones in different cases. Specifically, S2Snet achieves an improvement of 3.41% and 2.37% for PSNR and SSIM, respectively, as compared to the original Self2Self network, while such improvements become 19.9% and 22.7% as compared with the well-known non-deep learning NWSR method.
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.