A concept for human use of real-time and remote monitoring of diabetic subjects using intermittent scanned continuous glucose measurement.

Jhon E Goez-Mora, Natalia Arbeláez-Córdoba, Norman Balcazar-Morales, Pablo S Rivadeneira

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Jhon E Goez-MoraGrupo GITA, Facultad de Minas, Universidad Nacional de Colombia, Carrera 80#65-223, 050001, Medellín, Colombia.
Natalia Arbeláez-CórdobaGrupo GENMOL, Departamento de Fisiología y Bioquímica, Facultad de Medicina, Universidad de Antioquia, 050001, Medellín, Colombia.
Norman Balcazar-MoralesGrupo GENMOL, Departamento de Fisiología y Bioquímica, Facultad de Medicina, Universidad de Antioquia, 050001, Medellín, Colombia.
Pablo S RivadeneiraGrupo GITA, Facultad de Minas, Universidad Nacional de Colombia, Carrera 80#65-223, 050001, Medellín, Colombia. psrivade@unal.edu.co.
Universidad de Antioquia · COUniversidad Nacional de Colombia · CO

Funding

Universidad Nacional de Colombia 57528
6 · The paper itself

Abstract

backgroundFlash glucose monitoring systems like the FreeStyle Libre (FSL) sensor have gained popularity for monitoring glucose levels in people with diabetes mellitus. This sensor can be paired with an off-label converted real-time continuous glucose monitor (c-rtCGM) plus an ad hoc computer/smartphone interface for remote real-time monitoring of diabetic subjects, allowing for trend analysis and alarm generation.

objectivesThis work evaluates the accuracy and agreement between the FSL sensor and the developed c-rtCGM system. As real-time monitoring is the main feature, the system's connectivity was assessed at 5-min intervals during the trials.

methodsOne week of glucose data were collected from 16 type 1 diabetic rats using the FSL sensor and the c-rtCGM. Baseline blood samples were taken the first day before inducing type 1 diabetes with streptozotocin. Once confirmed diabetic rats, FSL and c-rtCGM, were implanted, and to improve data matching between the two monitoring devices, the c-rtCGM was calibrated to the FSL glucometer readings. A factorial design 2 × 3^3 and a second-order regression was used to find the base values of the linear model transformation of the raw data obtained from the sensor. Accuracy, agreement, and connectivity were assessed by median absolute relative difference (Median ARD), range averaging times, Parkes consensus error grid analysis (EGA), and Bland-Altman analysis with a non-parametric approach.

resultsCompared to the FSL sensor, the c-rtCGM had an overall Median ARD of 6.58%, with 93.06% of results in zone A when calibration was not carried out. When calibration frequency changed from every 50 h to 1 h, the overall Median ARD improved from 6.68% to 2.41%, respectively. The connectivity evaluation showed that 95% of data was successfully received every 5 min by the computer interface. CONCLUSIONS AND CLINICAL IMPORTANCE: The results demonstrate the feasibility and reliability of real-time and remote subjects with diabetes monitoring using the developed c-rtCGM system. Performing calibrations relative to the FSL readings increases the accuracy of the data displayed at the interface.

Indexed as

Diabetes Mellitus, ExperimentalDiabetes Mellitus, Type 1AnimalsBlood GlucoseBlood Glucose Self-MonitoringHumansRatsReproducibility of ResultsBlood GlucoseDiabetes mellitusFlash glucose monitoring systemInterstitial glucoseReal-time and remote monitoring

Identifiers

PMID38419031
PMCPMC10903066
OpenAlexW4392229829

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.