Evidence map›Paper›PMID 38455000›Full record

ArticleChemical science2024

Laser induced temperature-jump time resolved IR spectroscopy of zeolites.

Alexander P Hawkins, Amy E Edmeades, Christopher D M Hutchison, Michael Towrie, Russell F Howe, Gregory M Greetham, Paul M Donaldson

Abstract read
In one paragraph

Article in Chemical science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alexander P HawkinsCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory Didcot Oxon OX11 0QX UK paul.donaldson@stfc.ac.uk.ORCID https://orcid.org/0000-0002-5947-6631
Amy E EdmeadesCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory Didcot Oxon OX11 0QX UK paul.donaldson@stfc.ac.uk.ORCID https://orcid.org/0000-0001-7495-3355
Christopher D M HutchisonCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory Didcot Oxon OX11 0QX UK paul.donaldson@stfc.ac.uk.
Michael TowrieCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory Didcot Oxon OX11 0QX UK paul.donaldson@stfc.ac.uk.ORCID https://orcid.org/0000-0002-1305-701X
Russell F HoweDepartment of Chemistry, University of Aberdeen Aberdeen AB24 3UE UK.ORCID https://orcid.org/0000-0003-2462-8962
Gregory M GreethamCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory Didcot Oxon OX11 0QX UK paul.donaldson@stfc.ac.uk.ORCID https://orcid.org/0000-0002-1852-3403
Paul M DonaldsonCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory Didcot Oxon OX11 0QX UK paul.donaldson@stfc.ac.uk.ORCID https://orcid.org/0000-0002-0305-9142

Funding

Medical Research Council MR/S015574/1
6 · The paper itself

Abstract

Combining pulsed laser heating and time-resolved infrared (TR-IR) absorption spectroscopy provides a means of initiating and studying thermally activated chemical reactions and diffusion processes in heterogeneous catalysts on timescales from nanoseconds to seconds. To this end, we investigated single pulse and burst laser heating in zeolite catalysts under realistic conditions using TR-IR spectroscopy. 1 ns, 70 μJ, 2.8 μm laser pulses from a Nd:YAG-pumped optical parametric oscillator were observed to induce temperature-jumps (T-jumps) in zeolite pellets in nanoseconds, with the sample cooling over 1-3 ms. By adopting a tightly focused beam geometry, T-jumps as large as 145 °C from the starting temperature were achieved, demonstrated through comparison of the TR-IR spectra with temperature dependent IR absorption spectra and three dimensional heat transfer modelling using realistic experimental parameters. The simulations provide a detailed understanding of the temperature distribution within the sample and its evolution over the cooling period, which we observe to be bi-exponential. These results provide foundations for determining the magnitude of a T-jump in a catalyst/adsorbate system from its absorption spectrum and physical properties, and for applying T-jump TR-IR spectroscopy to the study of reactive chemistry in heterogeneous catalysts.

Identifiers

PMID38455000
PMCPMC10915812

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.