Evidence map›Paper›PMID 38464394›Full record

ArticleFrontiers in neuroergonomics2024

Cerebral oxygenation and perfusion kinetics monitoring of military aircrew at high G using novel fNIRS wearable system.

Thibault Roumengous, R Casey Boutwell, Jason Strohmaier, Jared Allen, Brett Goldbach, Nicholas Marotta, Tanner Songkakul, Shelby Critcher, Bria G Morse, Jeremy M A Beer and 1 more

Abstract read
In one paragraph

Article in Frontiers in neuroergonomics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Thibault RoumengousNIRSense Inc., Richmond, VA, United States.
R Casey BoutwellNIRSense Inc., Richmond, VA, United States.
Jason StrohmaierNIRSense Inc., Richmond, VA, United States.
Jared AllenNIRSense Inc., Richmond, VA, United States.
Brett GoldbachNIRSense Inc., Richmond, VA, United States.
Nicholas MarottaNIRSense Inc., Richmond, VA, United States.
Tanner SongkakulNIRSense Inc., Richmond, VA, United States.
Shelby CritcherNIRSense Inc., Richmond, VA, United States.
Bria G MorseAerospace Environment Protection Lab, KBR Science and Space Government Solutions Group, San Antonio, TX, United States.
Jeremy M A BeerAerospace Environment Protection Lab, KBR Science and Space Government Solutions Group, San Antonio, TX, United States.
Paul M ShermanUSAF 59th Medical Wing Science and Technology, San Antonio, TX, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Real-time physiological episode (PE) detection and management in aircrew operating high-performance aircraft (HPA) is crucial for the US Military. This paper addresses the unique challenges posed by high acceleration (G-force) in HPA aircrew and explores the potential of a novel wearable functional near-infrared spectroscopy (fNIRS) system, named NIRSense Aerie, to continuously monitor cerebral oxygenation during high G-force exposure. Methods: The NIRSense Aerie system is a flight-optimized, wearable fNIRS device designed to monitor tissue oxygenation 13-20 mm below the skin's surface. The system includes an optical frontend adhered to the forehead, an electronics module behind the earcup of aircrew helmets, and a custom adhesive for secure attachment. The fNIRS optical layout incorporates near-distance, middle-distance, and far-distance infrared emitters, a photodetector, and an accelerometer for motion measurements. Data processing involves the modified Beer-Lambert law for computing relative chromophore concentration changes. A human evaluation of the NIRSense Aerie was conducted on six subjects exposed to G-forces up to +9 Gz in an Aerospace Environmental Protection Laboratory centrifuge. fNIRS data, pulse oximetry, and electrocardiography (HR) were collected to analyze cerebral and superficial tissue oxygenation kinetics during G-loading and recovery. Results: The NIRSense Aerie successfully captured cerebral deoxygenation responses during high G-force exposure, demonstrating its potential for continuous monitoring in challenging operational environments. Pulse oximetry was compromised during G-loading, emphasizing the system's advantage in uninterrupted cerebrovascular monitoring. Significant changes in oxygenation metrics were observed across G-loading levels, with distinct responses in Deoxy-Hb and Oxy-Hb concentrations. HR increased during G-loading, reflecting physiological stress and the anti-G straining maneuver. Discussion: The NIRSense Aerie shows promise for real-time monitoring of aircrew physiological responses during high G-force exposure. Despite challenges, the system provides valuable insights into cerebral oxygenation kinetics. Future developments aim for miniaturization and optimization for enhanced aircrew comfort and wearability. This technology has potential for improving anti-G straining maneuver learning and retention through real-time cerebral oxygenation feedback during centrifuge training.

Indexed as

continuous monitoringdecompensationdeoxygenation kineticsfunctional near-infrared spectroscopyhigh-performance aircrafthypergravityphysiological episode detectiontissue oximetry

Identifiers

PMID38464394
PMCPMC10922194

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.