Clinical Evaluation of a New Spectral-Domain Optical Coherence Tomography-Based Biometer.

Jorge L Alió, Marina José-Martínez, Antonio Martínez-Abad, Alejandra E Rodríguez, Francesco Versaci, Jesper Hjortdal, Joaquim Neto Murta, Ana B Plaza-Puche, Mario Cantó-Cerdán, David P Piñero

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 3 countries.

Jorge L AlióResearch and Development Department, Vissum Grupo Miranza, 03016 Alicante, Spain.
Marina José-MartínezResearch and Development Department, Vissum Grupo Miranza, 03016 Alicante, Spain.
Antonio Martínez-AbadResearch and Development Department, Vissum Grupo Miranza, 03016 Alicante, Spain.
Alejandra E RodríguezResearch and Development Department, Vissum Grupo Miranza, 03016 Alicante, Spain.
Francesco VersaciCSO (Construzioni Strumenti Oftalmici), 50018 Scandicci, Italy.
Jesper HjortdalDepartment of Opthalmology, Aarhus University Hospital, 8000 Aarhus, Denmark.
Joaquim Neto MurtaDepartment of Opthalmology, University of Coimbra, 3000-548 Coimbra, Portugal.
Ana B Plaza-PucheResearch and Development Department, Vissum Grupo Miranza, 03016 Alicante, Spain.ORCID 0000-0001-5904-7530
Mario Cantó-CerdánResearch and Development Department, Vissum Grupo Miranza, 03016 Alicante, Spain.
David P PiñeroDepartment of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain.ORCID 0000-0002-1546-4807
Miranza · ESAarhus University Hospital · DKUniversitat de Miguel Hernández d'Elx · ESUniversity of Alicante · ESUniversity of Coimbra · PT

Funding

European Union´s Horizon 2020 research and innovation programme 878748
6 · The paper itself

Abstract

The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

Indexed as

anterior chamber depthaxial lengthcentral corneal thicknessoptical biometryspectral-domain optical coherence tomographyswept-source optical coherence tomography

Identifiers

PMID38473032
PMCPMC10931309
OpenAlexW4392517584

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.