Evidence map›Paper›PMID 38486774›Full record

ArticleHeliyon2024

Heart rate detection method based on Ballistocardiogram signal of wearable device:Algorithm development and validation.

Duyan Geng, Yue Yin, Zhigang Fu, Geng Pang, Guizhi Xu, Yan Geng, Alan Wang

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Duyan GengHebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China.
Yue YinHebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China.
Zhigang FuPhysical Examination Center of the Fourth Joint Logistics Support Unit of the 983rd Hospital of the Tianjin Chinese People's Liberation Army, Tianjin, 300142, PR China.
Geng PangHebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China.
Guizhi XuHebei University of Technology, State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Tianjin, 300130, PR China.
Yan GengHebei Institute for Drug and Medical Device Control, Shijiazhuang, 050200, PR China.
Alan WangCentre for Brain Research, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.
Hebei University of Technology · CNChinese People's Liberation Army · CNUniversity of Auckland · NZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Heart rate, as the four vital signs of human body, is a basic indicator to measure a person's health status. Traditional electrocardiography (ECG) measurement, which is routinely monitored, requires subjects to wear lead electrodes frequently, which undoubtedly places great restrictions on participants' activities during the normal test. At present, the boom of wearable devices has created hope for non-invasive, simple operation and low-cost daily heart rate monitoring, among them, Ballistocardiogram signal (BCG) is an effective heart rate measurement method, but in the actual acquisition process, the robustness of non-invasive vital sign collection is limited. Therefore, it is necessary to develop a method to improve the robustness of heart rate monitoring. Objective: Therefore, in view of the problem that the accuracy of untethered monitoring heart rate is not high, we propose a method aimed at detecting the heartbeat cycle based on BCG to accurately obtain the beat-to-beat heart rate in the sleep state. Methods: In this study, we implement an innovative J-wave detection algorithm based on BCG signals. By collecting BCG signals recorded by 28 healthy subjects in different sleeping positions, after preprocessing, the data feature set is formed according to the clustering of morphological features in the heartbeat interval. Finally, a J-wave recognition model is constructed based on bi-directional long short-term memory (BiLSTM), and then the number of J-waves in the input sequence is counted to realize real-time detection of heartbeat. The performance of the proposed heartbeat detection scheme is cross-verified, and the proposed method is compared with the previous wearable device algorithm. Results: The accuracy of J wave recognition in BCG signal is 99.67%, and the deviation rate of heart rate detection is only 0.27%, which has higher accuracy than previous wearable device algorithms. To assess consistency between method results and heart rates obtained by the ECG, seven subjects are compared using Bland-Altman plots, which show no significant difference between BCG and ECG results for heartbeat cycles. Conclusions: Compared with other studies, the proposed method is more accurate in J-wave recognition, which improves the accuracy and generalization ability of BCG-based continuous heartbeat cycle extraction, and provides preliminary support for wearable-based untethered daily monitoring.

Indexed as

BallistocardiogramBidirectional long short-term memory networkHeart rate detectionSleeping position

Identifiers

PMID38486774
PMCPMC10937685
OpenAlexW4392343491

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.