Evidence map›Paper›PMID 38534000›Full record

SynthesisThe Cochrane database of systematic reviews2024

Microwave coagulation for liver metastases.

Dawid Storman, Mateusz J Swierz, Jerzy W Mitus, Michal Pedziwiatr, Ning Liang, Robert Wolff, Malgorzata M Bala

Open access · greenAbstract readMeta-AnalysisReview
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Observational
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Dawid StormanChair of Epidemiology and Preventive Medicine, Department of Hygiene and Dietetics, Jagiellonian University Medical College, Krakow, Poland.
Mateusz J SwierzChair of Epidemiology and Preventive Medicine, Department of Hygiene and Dietetics, Jagiellonian University Medical College, Krakow, Poland.
Jerzy W MitusDepartment of Surgical Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Krakow Branch; Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.
Michal Pedziwiatr2nd Department of General Surgery, Jagiellonian University Medical College, Krakow, Poland.
Ning LiangCentre for Evidence-Based Chinese Medicine, Beijing University of Chinese Medicine, Beijing, China.
Robert WolffKleijnen Systematic Reviews Ltd, York, UK.
Malgorzata M BalaChair of Epidemiology and Preventive Medicine, Department of Hygiene and Dietetics, Jagiellonian University Medical College, Krakow, Poland.
Jagiellonian University · PLBeijing University of Chinese Medicine · CNKleijnen Systematic Reviews (United Kingdom) · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLiver metastases (i.e. secondary hepatic malignancies) are significantly more common than primary liver cancer. Long-term survival after radical surgical treatment is approximately 50%. For people in whom resection for cure is not feasible, other treatments must be considered. One treatment option is microwave coagulation utilising electromagnetic waves. It involves placing an electrode into a lesion under ultrasound or computed tomography guidance.

objectivesTo evaluate the beneficial and harmful effects of microwave coagulation versus no intervention, other ablation methods, or systemic treatments in people with liver metastases regardless of the location of the primary tumour. SEARCH

methodsWe used standard, extensive Cochrane search methods. The latest date of search was 14 April 2023. SELECTION CRITERIA: Randomised clinical trials assessing beneficial or harmful effects of microwave coagulation and its comparators in people with liver metastases, irrespective of the location of the primary tumour. We included trials no matter the outcomes reported. DATA COLLECTION AND ANALYSIS: We followed standard Cochrane methodological procedures. Our primary outcomes were: all-cause mortality at the last follow-up and time to mortality; health-related quality of life (HRQoL); and any adverse events or complications. Our secondary outcomes were: cancer mortality; disease-free survival; failure to clear liver metastases; recurrence of liver metastases; time to progression of liver metastases; and tumour response measures. We used risk ratios (RR) and hazard ratios (HR) with 95% confidence intervals (CI) to present the results. Two review authors independently extracted data and assessed the risk of bias using the Cochrane RoB 1 tool. We used GRADE methodology to assess the certainty of the evidence. MAIN

resultsThree randomised clinical trials fulfilled the inclusion criteria. The control interventions differed in the three trials; therefore, meta-analyses were not possible. The trials were at high risk of bias. The certainty of evidence of the assessed outcomes in the three comparisons was very low. Data on our prespecified outcomes were either missing or not reported. Microwave coagulation plus conventional transarterial chemoembolisation (TACE) versus conventional TACE alone One trial, conducted in China, randomised 50 participants (mean age 60 years, 76% males) with liver metastases from various primary sites. Authors reported that the follow-up period was at least one month. The trial reported adverse events or complications in the experimental group only and for tumour response measures. There were no dropouts in the trial. The trial did not report on any other outcomes. Microwave ablation versus conventional surgery One trial, conducted in Japan, randomised 40 participants (mean age 61 years, 53% males) with multiple liver metastases of colorectal cancer. Ten participants were excluded after randomisation (six from the experimental and four from the control group); thus, the trial analyses included 30 participants. Follow-up was three years. The reported number of deaths from all causes was 9/14 included participants in the microwave group versus 12/16 included participants in the conventional surgery group. The mean overall survival was 27 months in the microwave ablation and 25 months in the conventional surgery group. The three-year overall survival was 14% with microwave ablation and 23% with conventional surgery, resulting in an HR of 0.91 (95% CI 0.39 to 2.15). The reported frequency of adverse events or complications was comparable between the two groups, except for the required blood transfusion, which was more common in the conventional surgery group. There was no intervention-related mortality. Disease-free survival was 11.3 months in the microwave ablationgroup and 13.3 months in the conventional surgery group. The trial did not report on HRQoL. Microwave ablation versus radiofrequency ablation One trial, conducted in Germany, randomised 50 participants (mean age 62.8 years, 46% males) who were followed for 24 months. Two-year mortality showed an RR of 0.62 (95% CI 0.26 to 1.47). The trial reported that, by two years, 76.9% of participants in the microwave ablationgroup and 62.5% of participants in the radiofrequency ablation group survived (HR 0.63, 95% CI 0.23 to 1.73). The trial reported no deaths or major complications during the procedures in either group. There were two minor complications only in the radiofrequency ablation group (RR 0.19, 95% CI 0.01 to 3.67). The trial reported technical efficacy in 100% of procedures in both groups. Distant recurrence was reported for 10 participants in the microwave ablation group and nine participants in the radiofrequency ablation group (RR 1.03, 95% CI 0.50 to 2.08). No participant in the microwave ablation group demonstrated local progression at 12 months, while that occurred in two participants in the radiofrequency ablation group (RR 0.19, 95% CI 0.01 to 3.67). The trial did not report on HRQoL. One trial reported partial support by Medicor (MMS Medicor Medical Supplies GmbH, Kerpen, Germany) for statistical analysis. The remaining two trials did not provide information on funding. We identified four ongoing trials. AUTHORS'

conclusionsThe evidence is very uncertain about the effect of microwave ablation in addition to conventional TACE compared with conventional TACE alone on adverse events or complications. We do not know if microwave ablation compared with conventional surgery may have little to no effect on all-cause mortality. We do not know the effect of microwave ablation compared with radiofrequency ablation on all-cause mortality and adverse events or complications either. Data on all-cause mortality and time to mortality, HRQoL, adverse events or complications, cancer mortality, disease-free survival, failure to clear liver metastases, recurrence of liver metastases, time to progression of liver metastases, and tumour response measures were either insufficient or were lacking. In light of the current inconclusive evidence and the substantial gaps in data, the pursuit of additional good-quality, large randomised clinical trials is not only justified but also essential to elucidate the efficacy and comparative benefits of microwave ablation in relation to various interventions for liver metastases. The current version of the review, in comparison to the previous one, incorporates two new trials in two additional microwave ablation comparisons: 1. in addition to conventional TACE versus conventional TACE alone and 2. versus radiofrequency ablation.

Indexed as

Liver NeoplasmsMicrowavesRandomized Controlled Trials as TopicBiasCause of DeathDisease-Free SurvivalFemaleHumansMaleMiddle AgedNeoplasm Recurrence, LocalQuality of Life

Identifiers

PMID38534000
PMCPMC10966940
OpenAlexW4393224307

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.