Evidence map›Paper›PMID 38639779›Full record

ArticleCardiovascular and interventional radiology2024

Do Balloon Catheters have a Different Radial Force Along Their Longitudinal Axis?

Tae Won Choi, Jinoo Kim, Je Hwan Won

Open access · hybridAbstract readComparative Study
In one paragraph

Article in Cardiovascular and interventional radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 1 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Tae Won ChoiDepartment of Radiology, Ajou University School of Medicine, Ajou University Hospital, Suwon, Republic of Korea.
Jinoo KimDepartment of Radiology, Ajou University School of Medicine, Ajou University Hospital, Suwon, Republic of Korea.
Je Hwan WonDepartment of Radiology, Ajou University School of Medicine, Ajou University Hospital, Suwon, Republic of Korea. wonkwak@ajou.ac.kr.ORCID http://orcid.org/0000-0002-5901-295X
Ajou University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis experimental study was designed to compare radial forces between the central portion and both ends of balloon catheters when dilating stenosis. MATERIALS AND

methodsThree balloon catheters of 6 and 8 mm in diameter and of variable length were tested: Mustang, Conquest, and Genoss PTA. Cylindrical modules to position balloon catheters and install the measuring tip during radial force measurements were made using a 3D printer. The measuring tip created 20% stenosis at the inner lumen. Both ends and center of the balloon catheter were located at the measuring tip. The radial force was measured after inflating the balloon catheter to the rated burst pressure.

resultsFor the different diameters and lengths of balloon catheters and cylinder sizes, the median inccenter, the radial rease in radial force at the distal end compared to the center was 16.5% (range: 9.8-35.2%) for Mustang, 12.4% (range: 10.3-25.5%) for Genoss, and 7.4% (range: -0.3-13.1%) for Conquest balloon catheters. Similarly, compared to that at the force at the proximal end was 10.8% greater (range: -2.9-18.3%) for Mustang, 9.9% greater (range: 3.9-22.3%) for Genoss, and 7.3% greater (range: -1.3-12.4%) for Conquest catheters.

conclusionThe radial force is greater at both ends of the balloon than at the central portion, especially at the distal end. Dilation using the distal end of the balloon catheter is a practical method that can be applied in clinical practice without additional devices when encountering resistant stenosis, especially with semi-compliant balloons.

Indexed as

Equipment DesignAngioplasty, BalloonCathetersHumansPrinting, Three-DimensionalAngioplastyBalloon catheterRadial force

Identifiers

PMID38639779
PMCPMC11379730
OpenAlexW4394962421

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.