Evidence map›Paper›PMID 38674987›Full record

ArticlePolymers2024

Color and Chemical Stability of 3D-Printed and Thermoformed Polyurethane-Based Aligners.

Luka Šimunović, Sara Čekalović Agović, Antun Jakob Marić, Ivana Bačić, Eva Klarić, Flavio Uribe, Senka Meštrović

Abstract read
In one paragraph

Article in Polymers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Luka ŠimunovićDepartment of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.ORCID 0000-0003-2848-6041
Sara Čekalović AgovićSchool of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.
Antun Jakob MarićFaculty of Mechanical Engineering and Naval Architecture, University of Zagreb, 10000 Zagreb, Croatia.ORCID 0009-0008-2099-3237
Ivana BačićForensic Science Centre "Ivan Vučetić", Ministry of the Interior, 10000 Zagreb, Croatia.ORCID 0000-0003-0997-3960
Eva KlarićDepartment of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.
Flavio UribeDepartment of Orthodontics, School of Dental Medicine, University of Connecticut, Farmington, CT 06030, USA.
Senka MeštrovićDepartment of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.ORCID 0000-0003-3224-3579

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The significant rise in the use of clear aligners for orthodontic treatment is attributed to their aesthetic appeal, enhancing patient appearance and self-confidence. The aim of this study is to evaluate the aligners' response to common staining agents (coffee, black tea, Coca-Cola, and Red Bull) in color and chemical stability. Polyurethane-based thermoformed and 3D-printed aligners from four brands were exposed to common beverages to assess color change using a VITA Easyshade compact colorimeter after 24 h, 48 h, 72 h, and 7 days, as well as chemical stability using ATR-FTIR spectroscopy. The brand, beverage, and manufacturing method significantly influence color stability. ATR-FTIR analysis revealed compositional differences, with variations in response to beverage exposure affecting the integrity of polymer bonds. Color change analysis showed coffee as the most potent staining agent, particularly affecting Tera Harz TC85 aligners, while ClearCorrect aligners exhibited the least susceptibility. 3D-printed aligners showed a greater color change compared to thermoformed ones. Aligners with a PETG outer layer are more resistant to stains and chemical alterations than those made of polyurethane. Additionally, 3D-printed polyurethane aligners stain more than thermoformed ones. Therefore, PETG-layered aligners are a more reliable choice for maintaining the aesthetic integrity of aligners.

Indexed as

3D printingalignerscolorFourier transform infrared spectroscopy

Identifiers

PMID38674987
PMCPMC11054520

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked