Evidence map›Paper›PMID 38716156›Full record

ArticleAnalytical science advances2021

Improved intact peptide and protein quantitation by LC-MS: Battling the deleterious effects of analyte adsorption.

EmmaRae L Murphy, Andrew P Joy, Rodney J Ouellette, David A Barnett

Abstract read
In one paragraph

Article in Analytical science advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Comparative Analysis of Carbonic Anhydrase-II Expression Across Undescended Testes Sprague Dawley Model with Coenzyme Q10 Treatment.Acta informatica medica : AIM : journal of the Society for Medical Informatics of Bosnia & Herzegovina : casopis Drustva za medicinsku informatiku BiH · 2025
    Article
  2. Article
  3. Evaluation of Human Carbonic Anhydrase II (CA-II) Concentration Using ELISA: Insights into Optical Density's Role in Biomarker Quantification for Cryptorchidism Research.Acta informatica medica : AIM : journal of the Society for Medical Informatics of Bosnia & Herzegovina : casopis Drustva za medicinsku informatiku BiH · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

EmmaRae L MurphyAtlantic Cancer Research Institute Moncton New Brunswick Canada.
Andrew P JoyAtlantic Cancer Research Institute Moncton New Brunswick Canada.ORCID https://orcid.org/0000-0002-5477-1615
Rodney J OuelletteAtlantic Cancer Research Institute Moncton New Brunswick Canada.
David A BarnettAtlantic Cancer Research Institute Moncton New Brunswick Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Peptide and protein quantitation by liquid chromatography-mass spectrometry relies on the assumption of linear signal response with concentration. At low concentrations, analyte adsorption to pipette tips, sample vials and equipment can have significant deleterious effects on signal response. Meanwhile at high concentrations, linearity breaks down due to competitive ionization, signal suppression, and the formation of peptide or protein multimers. These effects result in calibration curves that are more sigmoidal than linear. Linearity at low protein levels for identification and quantitation is of paramount importance in the discovery and validation of biomarker molecules. Herein, we demonstrate the benefits of using commercial low-bind microcentrifuge tubes and LC vials on the response of a 27-mer peptide, Vn96, and the intact proteins apomyoglobin and carbonic anhydrase. Linear curves were acquired for Vn96 while apomyoglobin required the addition of intact carbonic anhydrase as an adsorption competitor to achieve linearity. A linear calibration curve for carbonic anhydrase was also acquired by using the polypeptide ubiquitin as an adsorption competitor and internal standard. Linear response was recorded for approximately two orders of magnitude for apomyoglobin and carbonic anhydrase and three orders of magnitude for Vn96 with detection limits ranging from 0.33 to 19 fmol/µL. Finally, we used low-bind vials for the online enzymatic digestion of apomyoglobin where a high concentration of apomyoglobin acted as an adsorption blocker for the low level trypsin enzyme. Fortunately, the liberated tryptic peptides showed no affinity for the walls of the low-bind vials. In this study, we take a comprehensive approach to combat analyte adsorption by showing the significance of utilizing low-bind vials and adsorption competitors to greatly improve upon signal sensitivity at low concentrations of target molecules. The use of these methodologies should improve the low-level detection of molecules by mass spectrometry.

Indexed as

adsorptionlow‐bind vialspeptideproteinquantitation

Identifiers

PMID38716156
PMCPMC10989528

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.