SynthesisAbdominal radiology (New York)2024
Dual-energy CT applications on liver imaging: what radiologists and radiographers should know? A systematic review.
Synthesis in Abdominal radiology (New York), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Liver enhancement using rapid kVp-switching dual-energy CT with reduced iodine contrast dose compared with single-energy CT with standard iodine dose: an intra-patient comparison.Abdominal radiology (New York) · 2026Article
- Italian radiologists and dual-energy CT: a state of the art from a shared document by the computed tomography subspecialty section of the Italian society of radiology.La Radiologia medica · 2025Article
- Evaluation of colorectal liver metastases using virtual monoenergetic images obtained from dual-layer spectral computed tomography.Abdominal radiology (New York) · 2025Article
- Impact of deep learning reconstructions on image quality and liver lesion detectability in dual-energy CT: An anthropomorphic phantom study.Medical physics · 2025Article
- Optimizing DSA parameters for enhanced radiation safety in interventional surgery.Frontiers in public health · 2025Article
- Research Progress of Dual-energy CT in Diagnosis and Evaluation of Curative Effect of Liver Cancer: A ReviewCurrent medical imaging · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis review aims to provide a comprehensive summary of DECT techniques, acquisition workflows, and post-processing methods. By doing so, we aim to elucidate the advantages and disadvantages of DECT compared to conventional single-energy CT imaging.
methodsA systematic search was conducted on MEDLINE/EMBASE for DECT studies in liver imaging published between 1980 and 2024. Information regarding study design and endpoints, patient characteristics, DECT technical parameters, radiation dose, iodinated contrast agent (ICA) administration and postprocessing methods were extracted. Technical parameters, including DECT phase, field of view, pitch, collimation, rotation time, arterial phase timing (from injection), and venous timing (from injection) from the included studies were reported, along with formal narrative synthesis of main DECT applications for liver imaging.
resultsOut of the initially identified 234 articles, 153 met the inclusion criteria. Extensive variability in acquisition parameters was observed, except for tube voltage (80/140 kVp combination reported in 50% of articles) and ICA administration (1.5 mL/kg at 3-4 mL/s, reported in 91% of articles). Radiation dose information was provided in only 40% of articles (range: 6-80 mGy), and virtual non-contrast imaging (VNC) emerged as a common strategy to reduce the radiation dose. The primary application of DECT post-processed images was in detecting focal liver lesions (47% of articles), with predominance of study focusing on hepatocellular carcinoma (HCC) (27%). Furthermore, a significant proportion of the articles (16%) focused on enhancing DECT protocols, while 15% explored metastasis detection.
conclusionOur review recommends using 80/140 kVp tube voltage with 1.5 mL/kg ICA at 3-4 mL/s flow rate. Post-processing should include low keV-VMI for enhanced lesion detection, IMs for tumor iodine content evaluation, and VNC for dose reduction. However, heterogeneous literature hinders protocol standardization.