ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2024
A sensitive and selective voltammetric method for the detection of pyrogallol in tomato and water samples using platinum electrode modified with alizarin red S film.
Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A Sensitive Cloud Point Extraction-Spectrophotometric Determination of Vanadium Using Pyrogallol and Aliquat 336.International journal of molecular sciences · 2026Article
- Carbon Quantum Dots Interactions with Pyrogallol, Benzoic Acid, and Gallic Acid: A Study on Their Non-Covalent Nature.Nanomaterials (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In contrast to the hyperactive platinum electrode, ARS modified platinum electrode presents a remarkable inertness toward adsorption and surface processes and lends it for further voltammetric applications. Measuring pyrogallol levels in samples is significant for assessing their antioxidant activity, which is crucial for understanding their potential health benefits and ability to combat oxidative stress. In addition, the excess consumption of pyrogallol can have significant negative effects on human health. A voltammetric sensor has been developed for the determination of pyrogallol using ARS modified platinum electrode. The electrode was prepared by electrodeposition of alizarin red S on a platinum electrode using cyclic voltammetry with a potential scan range of - 0.4 to 1.2 V against an Ag/AgCl quasi reference electrode for 60 cycles as optimum number of cycles. The modified electrode was characterized by CV and SEM techniques. This modified alizarin red S platinum electrode showed remarkable electrocatalytic performance and stability, resulting in a significant increase in pyrogallol oxidation current by 11.05% compared to the pyrogallol oxidative current at the unmodified platinum electrode. A well-defined oxidation peak was observed at ~ 0.40 V. The sensor exhibited a low limit of detection (LOD) of 0.28 µM and a linear standard curve covering the ranges of 1.0-40 µM and 0.01-10.0 mM pyrogallol. Extensive studies were performed to evaluate possible interferences from various organic and inorganic compounds and yielded satisfactory results that confirm the selectivity of the developed sensor for pyrogallol determination. In addition, the ARS-Pt electrode provided consistently reliable results for the accurate detection of pyrogallol in water and tomato samples.
Indexed as
Identifiers
38811524What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.