Evidence map›Paper›PMID 38829557›Full record

ArticleLangenbeck's archives of surgery2024

Scope transition and early arterial inflow control provide safe and comfortable dissection in robotic distal pancreatectomy.

Shoki Sato, Yosuke Inoue, Atsushi Oba, Yoshihiro Ono, Takafumi Sato, Hiromichi Ito, Yu Takahashi

Abstract read
PubMed Publisher
In one paragraph

Article in Langenbeck's archives of surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shoki SatoDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan.
Yosuke InoueDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan. yosuke.inoue@jfcr.or.jp.
Atsushi ObaDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan.
Yoshihiro OnoDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan.
Takafumi SatoDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan.
Hiromichi ItoDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan.
Yu TakahashiDivision of Hepato-biliary-pancreatic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe describe details and outcomes of a novel technique for optimizing the surgical field during robotic distal pancreatectomy (RDP) for distal pancreatic lesions, which has become common with potential advantages over laparoscopic surgery.

methodsFor suprapancreatic lymph node dissection and splenic artery ligation, we used the basic center position with a scope through the midline port. During manipulation of the perisplenic area, the left position was used by moving the scope to the left medial side. The left lateral position is optionally used by moving the scope to the left lateral port when scope access to the perisplenic area is difficult. In addition, early splenic artery clipping and short gastric artery dissection for inflow block were performed to minimize bleeding around the spleen. We evaluated retrospectively the surgical outcomes of our method using a scoring system that allocated one point for blood inflow control and one point for optimizing the surgical view in the left position.

resultsWe analyzed 34 patients who underwent RDP or R-radical antegrade modular pancreatosplenectomy (RAMPS). The left position was applied in 14 patients, and the left lateral position was applied in 6. Based on the scoring system, only the 0-point group (n = 8) had four bleeding cases (50%) with splenic injury or blood pooling; the other 1-point or 2-point groups (n = 13, respectively) had no bleeding cases (p = 0.0046).

conclusionOptimization of the surgical field using scope transition and inflow control ensured safe dissection during RDP.

Indexed as

PancreatectomyPancreatic NeoplasmsRobotic Surgical ProceduresSplenic ArteryAdultAgedDissectionFemaleHumansLaparoscopyLigationLymph Node ExcisionMaleMiddle AgedRetrospective StudiesTreatment OutcomeLeft side pancreatic tumorMinimally invasive surgeryPort hoppingRobotic distal pancreatectomySurgical view

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.